Skip to content

Robotic-Assisted Total Hip Arthroplasty Is Associated With Lower Prosthetic Complications in Patients With Lumbar Fusion or Stiff Spine: A Propensity-Matched Cohort Study.

Aug 2026 · Journal of the American Academy of Orthopaedic Surgeons · 0 citations · 32 references
Medicine

TL;DR

Robotic-assisted THA was associated with fewer complications than manual THA in patients with lumbar fusion or clinically relevant spinal stiffness, a population at elevated risk for instability after THA, and Precision-based implant positioning may improve outcomes in patients with altered spinopelvic mobility, including those without spinal fusion.

Abstract

Background

Patients with spinopelvic risk factors such as lumbar fusion or stiff spine exhibit a 5- to 10-fold increased risk of dislocation following total hip arthroplasty (THA), primarily due to altered spinopelvic mechanics that influence cup positioning. The utilization of robotic-assisted THA facilitates personalized planning, enhancing component placement in this high-risk population. This study aims to compare rates of implant-related and medical complications between robotic-assisted and manual THA in these high-risk patients.

Methods

Data were retrospectively obtained from the TriNetX Research Network. Patients with prior lumbar fusion or spinal conditions associated with stiffness or malalignment, and who subsequently underwent THA, were identified using ICD-10 and CPT codes. Procedure codes defined robotic-assisted and manual THA. After 1:1 propensity score matching for age, sex, body mass index, smoking status, and other comorbidities, outcomes were compared at 3, 6, 12 months and 2 years. A subgroup analysis compared both groups in spinal fusion (SF) and nonfusion (no-SF/stiff spine) patients.

Results

After 1:1 propensity score matching, each cohort included 2,147 patients. At 3 months, robotic THA was associated with lower prosthetic complications (1.4 vs 2.7%; odds ratio [OR]: 1.86, 95%; P = 0.01) and postoperative blood transfusion (0.9 vs. 1.8%; OR: 2.02, P = 0.01). At 1 year, dislocation was reduced (0.9 vs. 1.8%; OR: 2.07; P = 0.01). Revisions were also lower at 1 and 2-year follow-up in the robotic group (1.7 vs. 2.7%, OR: 1.61; 2.0 vs 3.7%, OR: 1.86; all P < 0.05; respectively), and the manual group had 1.9 times the hazard of having revision surgery at 2 years (HR: 1.9, 95%; P = 0.02). In no-SF patients, robotic THA was associated with markedly lower rates of prosthetic complications and revision surgery.

Conclusion

Robotic-assisted THA was associated with fewer complications than manual THA in patients with lumbar fusion or clinically relevant spinal stiffness, a population at elevated risk for instability after THA. Precision-based implant positioning may improve outcomes in patients with altered spinopelvic mobility, including those without spinal fusion.

View source

Similar papers

Open access Sep 2026

Comparative Analysis of Robotic-Assisted and Manual Total Knee Arthroplasty in Patients with Extra-Articular Deformities: A Propensity Score-Matched Prospective Cohort Study

RA-TKA was associated with a significantly lower rate of mechanical axis outliers and higher functional outcome scores at 12 months compared with manual TKA in patients with EAD, and the advantage may be most pronounced in severe and multiplanar deformities, but adequately powered studies are needed to confirm these fi...

G. Ayrapetov, D. Suleymanyants, I. Dmitrov et al. · 0 citations
Review Open access Sep 2026

Validation of the Accuracy of Robotic Arm-Assisted Total Hip Arthroplasty After Rotational Acetabular Osteotomy: A Propensity-Matched Controlled Study

Background Robot-assisted total hip arthroplasty (THA) improves the accuracy of implant placement. However, acetabular cup positioning in patients with a history of pelvic osteotomy remains technically demanding, and the benefit of robotic assistance in such cases has not been established. This study aimed to evaluate...

Yohei Matsushita, Hajime Sugiyama, T. Hayama et al. · 0 citations
Oct 2026

Higher femoral periprosthetic fracture rate with dual-mobility compared with single-mobility total hip arthroplasty : a retrospective propensity-matched study of 780 uncemented hips.

Aims Dual-mobility implants have reduced dislocation rates in total hip arthroplasty (THA), particularly in high-risk populations. However, under conditions of high stress, such as a fall or forced range of motion, the energy that would otherwise cause dislocation is instead transmitted distally along the femoral compo...

Mehdi Komat, Liam Sabot, Filip Simion et al. · 0 citations
Open access Sep 2026

Functional alignment with robotic-assisted total knee arthroplasty is associated with reduced early postoperative pain and alignment outliers compared to mechanical alignment with conventional total knee arthroplasty: a prospective cohort study

Introduction: Robotic-assisted total knee arthroplasty (RATKA) has been introduced to enhance surgical precision, alignment, and soft-tissue balancing, thus enabling the advent of numerous alignment philosophies including functional alignment (FA). This study aimed to compare early clinical outcomes, patient-reported o...

Wai-Kit Wong, N. Che-Kamaruddin, Patrick Ze-En Ng et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.