BeatFlow-ECG: Rectified Flow for ECG Reconstruction from Indirect Wearable Signals

Oct 2026 · 0 citations · 51 references
Computer Science Engineering

TL;DR

BeatFlow-ECG is presented, a conditional rectified-flow model for reconstructing single-channel ECG from synchronized PPG and inertial measurements and achieves the best results among the evaluated deterministic, adversarial, and diffusion-based baselines across all reported waveform and beat-timing metrics.

Abstract

Continuous cardiac monitoring outside clinical settings requires signals that are both informative and practical to collect during daily life. Electrocardiography (ECG) provides rich information about cardiac rhythm and waveform morphology, while wearable photoplethysmography (PPG) is easier to acquire continuously but is only an indirect cardiovascular measurement and is highly sensitive to motion. We present BeatFlow-ECG, a conditional rectified-flow model for reconstructing single-channel ECG from synchronized PPG and inertial measurements. BeatFlow-ECG models reconstruction as conditional transport from noise to ECG using a convolutional encoder-decoder with a transformer bottleneck and explicit flow-time conditioning. Motion information is incorporated through IMU-derived conditioning features, motion-dependent loss weighting, and an easy-to-hard training curriculum. We evaluate the model under leave-one-subject-out protocols on PPG-DaLiA and WESAD. BeatFlow-ECG achieves the best results among the evaluated deterministic, adversarial, and diffusion-based baselines across all reported waveform and beat-timing metrics, with Pearson correlations of 0.983 and 0.986 and R-peak F1 scores of 0.946 and 0.955, respectively. Compared with Conditional DDPM-1D, L1 error decreases from 0.085 to 0.062 on PPG-DaLiA and from 0.074 to 0.055 on WESAD. Additional analyses on PPG-DaLiA show higher correlation in fixed R-peak-relative waveform regions and lower reconstruction error across low-, medium-, and high-motion subsets.

View source

Similar papers

Preprint Aug 2026

CardioFusion-AI: Robust ECG--PPG Fusion for Multimodal Physiological Monitoring Under Signal Degradation

Wearable electrocardiogram (ECG) and photoplethysmogram (PPG) sensors are complementary but individually fragile: motion artifact, poor contact, and sensor dropout can degrade one or both signals. Fusion strategies that assume both modalities are equally trustworthy can become less reliable than a single clean modality...

Navaneetha Krishnan Kamalakannan, J. Kamalakannan · 1 citation
Preprint Sep 2026

DiSR-ECG: Residual Shifting Conditional Diffusion for Robust ECG Super-Resolution

Electrocardiogram (ECG) signals are essential for arrhythmia diagnosis. With the growing adoption of long-term monitoring via wearable and portable devices, energy-efficient acquisition has become critical, motivating the development of ECG super-resolution (SR) techniques to reconstruct high-resolution signals from lo...

Fan-Yi Hsu, I. Chiu, Kuan-Chen Wang et al. · 0 citations
Preprint Aug 2026

Test-Time Adaptation for ECG Classification via SQI-Gated Self-Training and Beat-Rhythm Consistency

Deep learning models for electrocardiogram (ECG) classification often suffer from significant performance degradation when deployed in unseen domains due to shifts in acquisition devices and patient populations. Test-time adaptation (TTA) offers a practical solution by adapting models using only unlabeled data at infer...

Wen-Han Jiang, Zhi-Peng Deng, Jia-Le Zhou et al. · 0 citations
Conference Sep 2026

Comparative Evaluation of CNN Architectures for Wearable Heartbeat Detection Using Multimodal ECG and PPG Signals

Wearable heartbeat monitoring has become increasingly important for continuous cardiovascular assessment in daily life. However, reliable heartbeat detection remains challenging under ambulatory conditions due to motion artefacts and signal degradation. Electrocardiography (ECG) provides reliable measurements of cardia...

Ziti Fariha Mohd Apandi, Al-Fahim Mubarak-Ali, Abdul Sahli Fakharudin · 0 citations
Open access Aug 2026

ECG-ARD: Autoregressive ECG Denoising With Dual-Domain Fusion and a Vector-Quantized Bottleneck.

Electrocardiogram (ECG) recordings are frequently corrupted by nonstationary artifacts such as baseline wander, muscle activity, and electrode motion, which can distort waveform morphology, reduce signal quality, and compromise downstream analysis. Although recent deep learning approaches have improved signal-level fid...

Thanaporn Viriyasaranon, J. Choi · 0 citations
#explainable ai Open access Oct 2026

Leveraging the wearable 1-lead ECG signal. From cardiac rhythm to cardiac function assessment

Traditional 12-lead ECGs offer comprehensive insights into the electrical activity of the heart, but require clinical settings and expert interpretation, which limits their accessibility. Smartwatch 1-lead ECGs can be recorded at home, allowing more frequent and rapid monitoring, opening opportunities for early adver...

V. van der Valk, D. Atsma, Roderick W. C. Scherptong et al. · 0 citations

Related blog posts

MIT News · Artificial Intelligence Oct 23, 2026

Q&A: How AI came to model the “messy” human mind

Assistant Professor Benjamin Lindquist studies how engineers deliberately injected randomness into early AI, giving rise to deep-learning models that sometimes hallucinate.

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.