Abstract
High-voltage direct-current (HVDC) transmission schemes are designed for high transfer capability and long-distance delivery. Still, their reliability can be significantly affected by lightning, as even relatively infrequent lightning faults can interrupt large power transfers. This study examines the lightning performance of the positive and negative poles of the Inga–Kolwezi ±500 kV HVDC scheme in the Democratic Republic of Congo, with particular attention to the unusual configuration in which the two poles are implemented as independent monopolar lines. The supplied technical record describes a 517 km section of the approximately 1,700 km scheme and provides system, fault, lightning-exposure and lightning-detection information. The methodology combines a review of the line configuration and insulation parameters, analysis of operational fault records, and interpretation of Fault Analysis and Lightning Location System (FALLS) Small Area Exposure (SAE) data over ten years from 1 April 2010 to 1 April 2020 within a 1 km buffer around each line. The theoretical interpretation is based on electro-geometric and leader-progression concepts and on the polarity-dependent interaction between the DC operating voltage and negative downward lightning. The source record reports lightning-related faults between 2015 and 2023, including ten shielding-failure events and five back-flashovers, with shielding-failure events associated with comparatively low peak currents, including 15 and 35 kA, while back-flashovers are associated with much higher reported amplitudes of 105 and 135 kA. The supplied material further indicates that a positive 500 kV pole can have a substantially increased shielding-failure rate under a negative downward leader, whereas the negative pole is more susceptible to direct negative-stroke flashover and the positive pole to back-flashover. These results support the conclusion that lightning performance cannot be evaluated from shielding geometry alone; pole polarity, conductor position, insulation coordination, grounding and the quality of lightning-location data must be considered jointly. The principal recommendation is therefore to complete the comparative assessment with pole-specific exposure and outage denominators and to use the resulting dataset to calibrate protection and maintenance priorities along the two independent lines.
Very Fast Transient Overvoltages (VFTOs) are one of the major insulation stress phenomena encountered in Gas
Insulated Substations (GIS). VFTOs are generated primarily during disconnector switching operations and are characterized by
extremely steep wavefronts, high frequency oscillations, and short durations. These tr...
M. Prabhakar, V. Anil, I. Chandramouli et al.· International Journal for Re...· 0 citations
This paper analyses the causes of outages in transmission substations, with a particular focus on flashovers occurring on insulator strings and busbars in facilities operating at voltage levels of 110 kV and 220 kV. Special attention is given to flashovers on insulators, recognised as one of the most frequent causes of...
Multi-circuit overhead distribution lines are increasingly used in medium voltage networks because they improve corridor utilization and reduce construction cost. However, their compact phase arrangement, shared pole structure, relatively low insulation level, and grounding constraints make them vulnerable to both dire...
Lin Chen, Lu-Ye Chen, Jun He et al.· Journal of Physics, Conferen...· 0 citations
Lightning surge interaction in distribution networks can produce severe fast-front transient overvoltages, insulation stress, back-flashover, and transformer terminal voltage escalation. This study evaluates the effectiveness of surge arrester placement in a 33 kV radial distribution network using PSCAD/EMTDC electroma...
S. I. K. S. A. Raif, H. Halim, N. M. Mukhtar et al.· 2026 2nd International Confe...· 0 citations
Lightning-induced failures on overhead transmission lines (OHTLs), particularly backflashover and shielding failure, represent persistent threats to power system reliability. Despite a growing body of technical literature, no systematic mapping of the global knowledge structure of this domain exists. This bibliometric...
Lailatul Niza Muhammad, M. A. Ab. Kadir· Engineering Research Express· 0 citations
To address the inherent contradiction in the required parallel gap distance of transmission-line insulated ground wires under lightning protection and ice-melting conditions, as well as the high safety risk and low operational efficiency associated with conventional manual gap adjustment methods, this paper proposes a...
Feng Xiao, Kai Xun, Xin-Min Li et al.· Journal of Physics, Conferen...· 0 citations