Skip to content
Open access

SDFStent: Real-time interactive virtual stenting via SDF deformation fields.

Sep 2026 · Computer Methods and Programs in Biomedicine · Vol 287, pp. 109645 · 0 citations · 53 references
Medicine

TL;DR

SDFStent produces simulation-ready post-stent models that match prescribed stent dimensions at interactive speeds, from pre-operative anatomy and catheterization data alone, and enables automated generation of large synthetic cohorts for data-driven surrogate modeling.

Abstract

Background

AND

Objective

Stenting is among the most common transcatheter interventions for congenital heart disease (CHD). Patient-specific computational fluid dynamics (CFD) simulations can predict hemodynamic outcomes of intervention scenarios but require post-operative vascular geometries that reflect stent-induced shape changes, which existing tools either model inadequately or require extensive time or manual effort to generate. We present SDFStent, a signed distance function (SDF) based mesh deformation method for virtual stenting that operates in real time, maintains mesh integrity, and preserves junction geometry.

Methods

The stent is modeled as a pipe surface composed of piecewise-capsule SDFs joined by a smooth-minimum operator. Mesh vertices near the expanding SDF surface are displaced along the SDF gradient with a compactly supported fall-off function and an alpha blending mask. SDFStent was benchmarked against three existing approaches and validated on a proof-of-concept cohort of three tetralogy of Fallot (ToF) and three coarctation of the aorta (CoA) patients using rigid-wall steady-state CFD simulations against clinical catheterization measurements.

Results

Against a prescribed diameter of 6.0 mm, the method produced a mean stented diameter of 5.92 ± 0.08 mm in 1.5 s, over 100× faster than the best stenting-specific comparator. All output meshes were watertight and self-intersection-free. CFD-simulated post-operative pressure drops agreed with clinical measurements within 4 mmHg (mean error 2 mmHg).

Conclusions

SDFStent produces simulation-ready post-stent models that match prescribed stent dimensions at interactive speeds, from pre-operative anatomy and catheterization data alone. The implementation is open-source and available in 3D Slicer. Its scriptable architecture enables automated generation of large synthetic cohorts for data-driven surrogate modeling.

Read PDF

Similar papers

Open access Oct 2026

Patient-specific hemodynamic evaluation of fenestrated physician-modified endografts in complex abdominal aortic aneurysms

Physician-modified endografts (PMEGs) are increasingly used for complex abdominal aortic aneurysms (AAA), but the patient-specific flow consequences of the geometric reconstruction are not well quantified. This study evaluated PMEG-associated changes in hemodynamic and wall-mechanical surrogate markers. Eigh...

Xiao-Long Du, Shi-Chen Jiang, Hong-Yue Zhang et al. · 0 citations
Open access Sep 2026

Position-Dependent Hemodynamics of Popliteal Artery Stent Grafts: The POPFLEX Study

Background: Endovascular exclusion of popliteal artery aneurysms (PAAs) with long covered stent-grafts is valuable for patients unfit for open surgery but is undermined by late stent thrombosis, even in fully scaffolded segments without kinking, a failure best clarified by computational fluid dynamics (CFD), which requ...

Christos Chronis, K. Tzirakis, N. Kontopodis et al. · 0 citations
Preprint Oct 2026

From Simulation to Suture Lines: Computational Fluid Dynamic Simulation-Guided Baffle Construction for Complex Biventricular Repair

Biventricular repair is favored for children with complex double-outlet right ventricle (DORV) to eliminate the long-term morbidity of single ventricle physiology. However, creating a baffle that maintains adequate cross-sectional area while limiting incursion on the tricuspid valve apparatus is challenging in a distor...

Alexander K. Reed, Elena Sabdy Martinez, Alexander D. Kaiser et al. · 0 citations
#artificial intelligence Preprint Sep 2026

Cross-Anatomy Transfer Versus Sparse Interpolation in Digital-Twin-Oriented Aortic Fluid-Structure Interaction Surrogates

Surrogate credibility for fluid-structure interac- tion (FSI) requires distinguishing transfer across independent anatomies from interpolation within an already sampled surface. Four de-identified human aortic models from the Vascular Model Repository were reconstructed into separate lumen and nominal 1.5-mm wall domai...

A. Nourbakhsh, M. Niroomand, E. Nourbakhsh · 0 citations
Open access Aug 2026

Enhancing Surgical Strategy for Raghib Syndrome by Virtual and Augmented Reality Tools

Background/Objectives: Raghib syndrome is a rare congenital heart disease where the left superior vena cava (LSVC) drains into the left atrium in addition to an absent coronary sinus and an atrial septal defect. This condition can lead to hemodynamic impairment and ultimately put the patient at a high risk of stroke. W...

Eleonora Costagliola, S. Pasta, G. Gentile et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.