Empirical findings demonstrate that the proposed DSS infrastructure significantly enhances predictive maintenance reliability in domestic SPP projects while substantially reducing operational downtime and technical maintenance costs.
Abstract
The efficient and safe operation of Solar Power Plants (SPP) depends on the autonomous detection of photovoltaic (PV) faults. In this thesis, an original multimodal Decision Support System (DSS) based on electrical analytics and computer vision was designed by processing multidimensional chronological sensor data obtained from a 10 kWp domestic PV system installed in the Van/Başkale region under varying seasonal conditions and operational scenarios.
In the first stage, the fault detection performances of Machine Learning (ML) and Deep Learning (DL) architectures were compared on sensor data. A lightweight ML layer was constructed through statistical residual analysis, utilizing the Isolation Forest algorithm for unsupervised pre-filtering and the HistGradientBoosting (HGB) model for supervised power estimation. This infrastructure was benchmarked against a 1D-CNN-LSTM Hybrid Autoencoder architecture, which hierarchically learns temporal and spatial features, based on accuracy, F1-Score, and computational cost criteria. To clarify the "black box" nature of the deep learning model, an Explainable AI (XAI) layer was established by integrating the SHAP algorithm into the system.
In the second stage, to autonomously verify the physical causes of electrical anomalies (such as micro-cracks, fractures, soiling, and shading), panel images collected from the field were labeled on Roboflow and trained using the Transformer-based RF-DETR object detection architecture. Physical deformations were successfully mapped with a confidence score exceeding 95%.
In the final stage, all analytical and visual models were integrated into a unified user interface using the Antigravity infrastructure. The developed DSS fuses two different data sources to provide the operator with instantaneous "Predicted Percentage of Efficiency Loss (%)" and action-oriented "Maintenance Recommendations." Empirical findings demonstrate that the proposed DSS infrastructure significantly enhances predictive maintenance reliability in domestic SPP projects while substantially reducing operational downtime and technical maintenance costs.
This study aimed to develop and implement a cloud-enabled intelligent fault inference system for a photovoltaic installation, using locally acquired electrical and environmental data, preprocessed prior to cloud-based inference.
C. D. de Lima, Mariana da S. M. Sobral, Paulo F. C. Barbosa· Revista Brasileira de Engenh...· 0 citations
A new stacking-ensemble hybrid machine learning model that will combine a one-dimensional convolutional neural network with a bidirectional long short-term memory (CNN-BiLSTM) module, a Random Forest classifier, and an XGBoost gradient booster as base learners under the guidance of a logistic regression meta-learner is...
A. Gopalakrushna· Materials Research Proceedin...· 0 citations
A novel hybrid intelligent classification system for PV fault detection is proposed by integrating Fuzzy C-Means (FCM) clustering and Deep Learning (DL) techniques such as Multi-Layer Perceptron (MLP), Long Short-Term Memory (LSTM), Bidirectional LSTM (BiLSTM) and Gated Recurrent Unit (GRU).
V. Vignesh, R. S. Kumar, G. Suganeshwari· Frontiers in Artificial Inte...· 0 citations
A rule-based classification approach in which IF–THEN decision rules are intelligently generated using Discrete Tuna Swarm Optimization ensures that diagnosis decisions are not only accurate but also understandable, offering a clear alternative to black-box models.
Souria Sif, Ouahiba Chouhal, Yassine Beddiaf et al.· Journal of Communications So...· 1 citation
Results indicate that artificial intelligence can significantly strengthen the resilience and automation of next-generation smart grid infrastructures.
T. Anvesh, Akshaya Chelpuri, Ambati Chandu· International Scientific Jou...· 0 citations
A novel framework that integrates Extended Kalman Filter (EKF) state estimation with uncertainty-aware graph learning for photovoltaic (PV) array fault detection and localization and demonstrates strong robustness to sensor noise and transient faults by leveraging physical uncertainty to guide graph topology.
Saud Wasly, N. Abu-Hamdeh· Scientific Reports· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.