Skip to content
Open access

Investigation of Fresh Concrete Lateral Pressure on Single-Sided Wall Formwork: Using Embedded Pressure Sensors

Aug 2026 · Buildings · Vol 16, pp. 3413 · 0 citations · 26 references

Abstract

A full-scale field investigation was performed to evaluate the lateral pressure exerted by fresh concrete on a 6.67 m-high single-sided wall formwork during on-site casting. Five embedded pressure sensors were installed at various elevations to enable high-frequency, real-time monitoring of pressure evolution throughout the casting process. The experimental programme captured the combined effects of casting rate, staged placement, internal vibration, and casting interruptions, and the measured results were compared with widely used design models (ACI 347R-14, DIN 18218, and CIRIA R108). The results indicate a strongly non-hydrostatic pressure distribution, with a maximum pressure of 56 kN/m2 occurring at an intermediate height, rather than at the base, exceeding the design value by more than twice. Transient pressure peaks were closely associated with vibration, while casting interruptions promoted thixotropic structural build-up and reduced pressure recovery in lower regions. Comparison with design models demonstrates that commonly used approaches may significantly underestimate peak pressures unless conservative assumptions or calibrated parameters are applied. These findings provide rare full-scale field evidence of time-dependent and vibration-induced pressure behaviour and highlight the importance of real-time monitoring for capturing transient effects. The study contributes to an improved understanding of fresh concrete behaviour in single-sided wall systems and supports the development of safer, more reliable formwork design approaches.

Read PDF

Similar papers

Open access Oct 2026

Experimental study on lateral pressure of prefabricated block formwork for rock-fill concrete dam

Prefabricated block formwork has been increasingly used in rock-fill concrete (RFC) dam construction. However, the lateral pressure characteristics of such formwork under fresh self-compacting concrete (SCC) have not been fully investigated. This paper presents a systematic experimental study on the lateral pressure...

Qing Zhao, Zuo-Qing Guo, Hui-Yong Liu et al. · 0 citations
Open access Oct 2026

Mechanical response of large-span variable-cross-section tunnels: insights from numerical simulation and field monitoring

Surrounding rock deformation and loosening zone thickness are critical parameters for tunnel support design and stability evaluation. This study examined the variable-cross-section Qingshan Tunnel on the Ren-Zun Expressway. Systematic field monitoring measured surrounding rock pressure, displacement, and loosening zone...

Nai-Tao Zheng, You-Yun Li, Zhi-Feng Wang et al. · 0 citations
Open access Sep 2026

Structural response of a single‐storey hall under localized fire exposure

A full‐scale fire experiment was conducted on a single‐storey steel portal frame to investigate structural behaviour under combined horizontal loading and localized fire exposure. The tested system consisted of a portal frame with thin‐walled purlins and trapezoidal steel sheeting. Prior to fire ignition, a horizontal...

B. Židlický, K. Cábová, M. Kuříková et al. · 1 citation
Dec 2026

Experimental Investigation of the Cold-Formed Steel Beam-to-Column Clip-Angle Screwed Connections at Ambient and Elevated Temperatures

The present study examines the behavior of beam-to-column cold-formed steel (CFS) clip-angle screwed connections in ambient and elevated-temperature conditions through a total of 49 experimental tests. The aspect ratio of the clip-angle, defined as the width-to-depth ratio, was varied from 0.19 to 0.96 by considering...

R. Madheswaran, M. Madhavan · 0 citations
Open access Oct 2026

Experimental study of a sustainable bed joint reinforcement for masonry

This paper presents an experimental program aimed at assessing the out-of-plane bending behaviour of brick masonry walls reinforced with a novel reinforcement system, consisting of high-strength steel cord mesh held together by an interwoven fiberglass roving. This experimental study evaluates a modern alternative to t...

Emerson Cuadros-Rojas, Larisa Garcia-Ramonda, Pere Roca et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.