Deploying a new control policy for voltage control in active distribution grids requires evidence that physical limits will be satisfied before the policy is tested on the physical grid. This assessment is difficult for two reasons. First, simulations cannot capture every disturbance, modeling error, and device interaction present in the real grid. Second, historical measurements reflect operation under existing control policies, whereas a new policy may drive the grid into different operating conditions. To address these challenges, we propose Distributionally Robust Conformal Safety Screening (DR-CSS), a policy-agnostic framework for pre-deployment, scenario-by-scenario screening of a new control policy using historical data and a nominal simulator. For each new scenario, the simulator predicts a future voltage trajectory for the whole grid; DR-CSS then constructs a conformal safety interval around this prediction using historical simulation-to-reality errors. The interval is further enlarged to account for closed-loop changes induced by the deployment of the new policy and its interactions with the remaining controllers. To the best of our knowledge, DR-CSS is the first framework in power systems to combine historical data from an existing control policy with an imperfect simulator for pre-deployment safety screening of a new policy. Experiments on the IEEE 33-bus and IEEE 141-bus systems evaluate the deployment of learning-based voltage control policies and show that DR-CSS identifies all unsafe test scenarios. To reduce unnecessary warnings on safe scenarios, we adapt the safety intervals to different operating conditions and gradually introduce new policies with recalibration after each stage. These extensions increase the informational value of the safety screening and support safer deployment decisions in active distribution grids.
This article presents a data-driven approach to minimally adjust forecast-based steady-state generation dispatch in electrical transmission networks. The goal is to manage congestion caused by uncertainty in demand and renewable generation under a fixed automatic generation control (AGC) policy operating without satura...
S. Balaraman, S. Srinivasan, K. Sundar· 0 citations
This paper presents a first-order robustness radius for thermal security of alternating-current power-system operating points. The radius is intended for post-dispatch screening in control-room studies, planning studies, and dispatch comparison, where engineers need to know which monitored line is closest to overload a...
The transition to renewable energy introduces significant voltage regulation challenges, particularly in radial feeders. While inverter-based Volt-VAr control offers a solution, standardised settings like IEEE 1547 often fail to address feeder-specific dynamics under high load or low generation conditions, leading to...
Karoline Ingebrigtsen, C. Bordin, Matteo Chiesa et al.· Discover Applied Sciences· 0 citations
The large-scale integration of renewable energy into electrical power systems places a growing reliance on grid-forming converters (GFMs) to overcome critical stability and control hurdles. By emulating a slowly varying voltage source behind a tunable resistive?inductive impedance, GFMs enable precise setpoint tracking...
Ružica Cvetanović, Lazar Stojanović, Paolo Sbabo et al.· 0 citations
Active distribution grids require analysis methods that combine physical fidelity with low computational cost for repeated screening, optimization workflows, and operational decision support. Local linearized power-flow models can support these tasks, but their accuracy depends strongly on the operating point around wh...
Yannick Hömmen, Daniel Müller, Fabian Auschra et al.· Energies· 0 citations
The continuous integration of inverter-based resources makes transient stability analysis increasingly important for power system modernization, in light of the intricate dynamics arising from large-scale inverter deployment. However, analytical transient stability analysis methods consistently yield overly conservativ...
Zhong Liu, Jialin Zheng, Jun-Jie Qin et al.· 0 citations