Skip to content
Open access

Rational Control of Antibody Orientation for Enhancing Sensitivity and Specificity in Lateral Flow Immunoassays With Clinical Validation.

Oct 2026 · Advanced Healthcare Materials · pp. e71815 · 0 citations · 40 references
Medicine

TL;DR

A universal strategy integrating orientation-controlled antibody conjugation at the immunoprobe with a biotin-streptavidin-modified test line to enhance LFA sensitivity, specificity, and analytical reliability is reported.

Abstract

Lateral flow assays (LFAs) are widely used for point-of-care diagnostics, but their sensitivity is often limited by inefficient antibody orientation and poor signal transduction. Herein, we report a universal strategy integrating orientation-controlled antibody conjugation at the immunoprobe with a biotin-streptavidin-modified test line to enhance LFA sensitivity, specificity, and analytical reliability. Using an orientation-controlled conjugation approach (P-6, Scheme 1), antigen accessibility was maximized while nonspecific adsorption and false-positive signals were suppressed. Compared with conventional randomly conjugated probes (P-3, Scheme 1) on unmodified test lines, the combined P-6/biotin-streptavidin configuration achieved limits of detection of 0.0352 ng/mL for cytokeratin 19 fragment (CYFRA21-1) and 0.0808 ng/mL for carcinoembryonic antigen (CEA), corresponding to sensitivity enhancements of approximately 14-19 fold. However, probe rankings get inverted across capture chemistries, indicating the importance of dual-site orientation. The universality of this strategy was further validated using alpha-fetoprotein (AFP), carbohydrate antigen 125 (CA125), carbohydrate antigen 15-3 (CA15-3), and prostate-specific antigen (PSA). Furthermore, multiplexed LFAs using fluorescent polymer dots enabled simultaneous detection of CYFRA21-1 and CEA with minimal cross-reactivity and were validated in 28 clinical serum samples against the hospital reference method.

Read PDF

Similar papers

Sep 2026

DNA origami-based lateral flow biosensors for detection of small molecule, protein, and nucleic acid.

A programmable DNA origami-based lateral flow assay (DO-LFA) that employs a triangular DNA origami nanostructure (TDON) as a tunable molecular scaffold offering a generalizable and scalable strategy for next-generation point-of-care diagnostics.

Bao-Hong He, Xi-Wei Wang, Xiao-Lu Han et al. · 0 citations
Review Oct 2026

From sensitivity challenges to nanozyme-driven signal amplification in lateral flow immunoassays for biomarker detection.

Disease-related molecular markers are central to early diagnosis, treatment evaluation, and prognostic prediction. Conventional laboratory techniques, such as enzyme-linked immunosorbent assays (ELISA), require multiple incubation and washing steps and depend on specialized instrumentation. These requirements limit the...

Ling Teng, Yong-Chao Yao, Yuan Yang et al. · 0 citations
Oct 2026

Advancing Multiplex Imaging: A Sequential Antigen Retrieval Protocol to Enhance Antibody Compatibility and Detection Sensitivity.

PURPOSE Antigen retrieval remains a major challenge in multiplex tissue imaging, as the conflicting requirements of antibodies often limit the use of certain antibodies within a panel. Various protocols for epitope retrieval were tested to develop a standardized method for optimizing signal detection for a broad range...

Yuna Delarue, M. Le Rochais, Nadège Marec et al. · 0 citations
Oct 2026

Ultrasensitive and Specific Detection of Neutralization-Correlated Serum Antibodies Via Secondary Antibody−DNA Linker-Mediated Magnetic Bead−Based Proximity Extension Assay

Sensitive, accurate, and readily deployable detection of neutralizing antibody (NAb) titers is essential for evaluating vaccine efficacy and population-level immunity. Here, we report an Antibody-DNA Linker (AND Linker) comprising a fusion of Protein A/G, a G4S flexible peptide, and duck circovirus replication initia...

Long Zhao, Yu-Jue Wang, Lin-Yu Xiao et al. · 0 citations
Open access Aug 2026

Yes/No Quantitative Analysis of Single-Stranded Oligonucleotides with Lateral Flow Assays

Accessible molecular diagnostics is fundamental to effective healthcare. While most current point-of-care devices detect only the presence of a molecular biomarker(s), biomarker quantification can be equally important for decision-making on disease treatment and containment. Here, we present a diagnostic platform that...

Niusha Hassandoost, Leslie Munoz, Kerrigan Kotecki et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.