Skip to content

ECGQuest: Benchmarking and Fine-Tuning Language Models for Electrocardiography

Aug 2026 · 0 citations · 39 references
Computer Science

TL;DR

ECGQuest provides a reproducible benchmark for contextual ECG knowledge and shows that parameter-efficient fine-tuning can make smaller language models competitive with substantially larger commercial models.

Abstract

Electrocardiogram (ECG) interpretation requires knowledge of cardiology, electrophysiology, clinical diagnosis, ECG waveforms, signal acquisition, and instrumentation. Existing language-model benchmarks, however, primarily assess broad medical knowledge or interpretation of individual ECG signals and images rather than the broader contextual knowledge required for ECG interpretation. We developed ECGQuest, a literature-grounded resource for evaluating and fine-tuning ECG-specific language models. A GPT-4o-based pipeline generated questions from 23 ECG references and Computing in Cardiology proceedings from 2003-2025. The final dataset contains 10,904 unique True/False questions paired with their negated forms (21,808 Q&A pairs). We evaluated three commercial and 20 open-source language models on a held-out test set in a zero-shot setting. Five open-source models with 7-14B parameters were fine-tuned using Low-Rank Adaptation, with BERT and BiomedBERT included as supervised encoder baselines. Generalization was assessed on ECG-related subsets of MedMCQA and MedQA converted to binary True/False questions using official answer keys. Zero-shot accuracy on ECGQuest ranged from 49.5% to 74.4%, with GPT-5 performing best. General-purpose models outperformed medically specialized models, several models showed strong True/False bias, and encoder baselines performed near chance. Fine-tuning improved all open-source models by 6.5-14.1%. Fine-tuned DeepSeek-R1-Distill-Qwen-14B reached 76.3% accuracy, while a five-model voting ensemble reached 78.5%. On MedMCQA and MedQA, fine-tuning mainly benefited weaker or class-biased models and did not consistently improve strong base models. ECGQuest provides a reproducible benchmark for contextual ECG knowledge and shows that parameter-efficient fine-tuning can make smaller language models competitive with substantially larger commercial models.

View source

Similar papers

Open access Sep 2026

BenchECG and xECG: a benchmark and baseline for ECG foundation models

Electrocardiograms (ECGs) are inexpensive, widely used, and well-suited to deep learning. Interest has grown in ECG foundation models that generalise across diverse downstream tasks. However, current evaluation rarely reflects the full capabilities expected of ECG foundation models, with prior work often using narrow...

R. Lunelli, A. Nicolson, S. Pröll et al. · 0 citations
Open access Aug 2026

AI-Assisted Multilabel Diagnosis of 12-Lead Electrocardiograms Using an Interpretable Stacked Deep Learning Model with External Validation

A compact and interpretable framework for five-superclass multi-label ECG diagnosis that integrates leakage-aware development, threshold-controlled testing, frozen external validation, and multimethod interpretability is developed.

A. Tassaddiq, Aiman J. Albarakati, Rabab Alharbi et al. · 0 citations
#artificial intelligence Preprint Sep 2026

TRACE: Expert-Aligned ECG Representation Learning with Rigorous Benchmarking and Real-World Validation in Acute Cardiac Care

A hybrid architecture that jointly learns unimodal and cross-modal representations via uncertainty-weighted multi-task learning while utilizing an LLM-based pipeline to extract high-fidelity findings from cardiologist reports is proposed.

L. Y. Panchumarthi, Andrew Lu, Saurabh Kataria et al. · 0 citations
Review 2026

Mamba—GCN: Fusion Framework for Interpretable Arrhythmia Diagnosis Using 12-Lead ECG Signals

It is demonstrated that hybrid spatio-temporal architectures can achieve diagnostic performance comparable to strong convo-lutional baselines while offering significantly improved trans-parency through a quantitative comparison of representative models and visual analysis of performance—interpretability trade-offs.

Rhivu Dutta, N. Suma · 0 citations
Preprint Aug 2026

Holtercare-Bench: A Multimodal Benchmark for Evaluating Long-Term Dynamic ECG Analysis

This work illuminates the limitations of current MLLMs in electrophysiology and provides a foundational benchmark for long-term medical MLLMs, including Holtercare-Bench, a multimodal benchmark that evaluates models on temporal localization, clinical diagnosis, and global summarization.

Yihan Xie, H. Cui, Runze Ye et al. · 0 citations

Related blog posts

Microsoft Research Blog Oct 22, 2026

Flint-interactive: A language for creating interactive data visualizations

Flint-interactive gives AI agents a language for creating interactive visualizations. Click a chart, filter data, highlight related content, and explore beyond the view the author originally chose. The post Flint-interactive: A language for creating interactive data visualizations appeared first on Microsoft Research.

MIT News · Artificial Intelligence Oct 15, 2026

AI model decodes the language cells use to communicate

A new computational approach reveals how cells communicate to assemble into tissues. This could accelerate stem cell engineering, improve disease models, and inform therapies.

Microsoft Research Blog Oct 15, 2026

Proof-based general-purpose computing with Magnetar

Zero-knowledge proofs can verify computing results without rerunning workloads or exposing sensitive data. Magnetar helps bring them into the mainstream with support for standard programming languages, major speed gains, and quantum-resistant security. The post Proof-based general-purpose computing with Magnetar appeared first on Microsoft Research.

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.