Sep 2026· Journal of Telecommunication, Electronic and Computer Engineering· Vol 18, pp. 9-16· 0 citations· 28 references
TL;DR
This study combined a bidirectional long short-term memory (Bi-LSTM) layer, which processed the waveform in both temporal directions, with two leaky integrate-and-fire spiking layers to maintain high ECG classification performance while shifting its later-stage processing to event-driven spike activity.
Abstract
Wearable ECG monitoring requires a classifier that can operate within a limited power budget. This study therefore combined a bidirectional long short-term memory (Bi-LSTM) layer, which processed the waveform in both temporal directions, with two leaky integrate-and-fire (LIF) spiking layers. The recurrent output was converted into sparse events, while a fast-sigmoid surrogate gradient enabled training through the nondifferentiable spike function using backpropagation through time. Twenty hyperparameter configurations were evaluated using 60-40, 70-30, and 80-20 training-testing partitions. The best configuration, Configuration 3 using the 80-20 partition, comprised one 64-unit Bi-LSTM layer, a membrane decay parameter of 0.85, and a learning rate of 0.00020. It achieved a training accuracy of 97.64% and a test accuracy 96.88%, exceeding the reporting accuracy of the standalone SNN by 5.21 percentage points. Thus, the model maintained high ECG classification performance while shifting its later-stage processing to event-driven spike activity.
Epilepsy is a condition that is present in 50 million individuals all over the world, but predicting seizures in real-time on wearable devices is a challenging task because of stringent power and latency requirements. The current paper introduces a wearable edge devices-based low-power seizure prediction system based o...
A. G. Jaber· Dijlah Journal of Engineerin...· 0 citations
Objectives This study highlights the importance of an appropriate encoding technique in Spiking Neural Networks, and proposes the use of multiresolution encoding, which combines multiple encodings based on input features. Methods This research experiments on The MITBIH dataset was split into train-test data using AAMI...
Sarita Mishra, S. Rautaray, R. Barik· F1000Research· 0 citations
Under leakage-controlled inter-patient evaluation, causal physiological representations enable an interpretable linear model to achieve efficient and competitive arrhythmia detection potentially suitable for resource-constrained wearable and bedside decision-support systems, matching the discriminative evidence exploit...
Moirangthem Tiken Singh, Manibhushan Yaikhom, R. K. Prasad· Computers in Biology and Med...· 0 citations
This study shows that a Spiking Neural Network (SNN), built on a regression-adapted Leaky Integrate-and-Fire (LIF) neuron, can estimate blood glucose from multi-frequency bioimpedance and auxiliary biosignals with clinically auditable accuracy at low computational and memory cost.
Matheus Willian Sprotte, P. Bertemes· Biosensors· 0 citations
The automated classification of cardiac arrhythmias in electrocardiogram (ECG) signals is critical for cardiovascular diagnosis. Several studies focus on the classification of ECG rhythms. However this task remains a challenge, as is often affected by significant class imbalances, long-term temporal dependencies and fi...
Jose H. Godoy-Gonzalez, V. Díaz-Ramírez, R. Juarez-Salazar· Optics and Photonics for Inf...· 0 citations
Space missions require reliable and safe physiological monitoring systems, as well as capable of continuous operation, as microgravity affects cardiovascular function and heart rhythm stability. This study develops and validates an intelligent in-ear photoplethysmography (PPG) system for continuous cardiac rhythm monit...
K. Azudin, Kok-Beng Gan, R. Jaafar et al.· Jurnal Kejuruteraan· 0 citations