This on-bench study compared different laser energy levels in five commercially available endografts to assess fabric damage and evaluate fenestration quality, dimensions, and recoil, finding that both low- and high-energy L-ISF were feasible across all tested grafts.
Abstract
(1) Background: Laser in situ fenestration (L-ISF) is an endovascular technique used to preserve target vessel patency in urgent or emergency endovascular aortic repair when fenestrated/branched solutions are unavailable or unsuitable, or as a bailout technique for fenestration or branch misalignment. This on-bench study compared different laser energy levels in five commercially available endografts to assess fabric damage and evaluate fenestration quality, dimensions, and recoil. (2) Methods: A total of 102 fenestrations were created using a 2.0 mm excimer laser catheter at low (45 mJ/mm2) or high (60 mJ/mm2) energy levels and dilated with a 6 mm plain balloon in five polyester endografts (Zenith Alpha, RelayPro, Endurant IIs, Valiant Captivia, Hercules). High-magnification microscopy assessed morphology and fabric damage after puncture, after dilation, and after 24 h. Quantitative measurements included diameters, area, and recoil under standardized study conditions. (3) Results: Valiant exhibited clearer puncture margins and no bulging; Hercules showed frequent tearing and more bulging and warp-aligned recoil at high energy. In Endurant IIs, low-energy L-ISF produced larger diameters and area but also greater recoil. RelayPro revealed stronger surface recoil with high energy. (4) Conclusion: Both low- and high-energy L-ISF were feasible across all tested grafts. A low-energy approach may be preferable for Endurant IIs, potentially reducing the risk of bridging stent graft stenosis.
BACKGROUND
Dedicated bridging stents for fenestrated and branched endovascular aortic repair (F/BEVAR) have recently become available. The BeFlared stent (Bentley InnoMed, Germany) is a balloon-expandable covered stent mounted on a dual-diameter balloon designed to allow simultaneous deployment and flaring. This study...
Tamas Kovacs, Andreas K. Johannessen, Jacob Budtz-Lilly et al.· Journal of Cardiovascular Su...· 0 citations
Objective: To assess the clinical use of the UltraScore balloon in a real-world setting. Methods: This is a prospective, multicenter, single-arm, real-world study to assess the clinical use of the UltraScore balloon for the treatment of stenotic lesions of the superficial femoral artery (SFA), popliteal and below-the-k...
Craig Walker, Robert E. Beasley, Kuldeep Singh et al.· Journal of Vascular Diseases· 0 citations
Background: Thulium fiber laser (TFL) and high-power Holmium:Yttrium-Aluminum-Garnet laser (HPHL) are common laser modalities used in flexible ureteroscopy (F-URS). Existing comparisons are imperfect due to lack of randomization, use of obsolete low-power settings, and the recent advent of technologies such as flexible...
K. Y. Fong, Han-Jie Lee, Pierre Yeap et al.· Therapeutic Advances in Urol...· 0 citations
OBJECTIVE
Open surgical conversion after EVAR is morbid and performed without disease-specific instruments. We evaluated the feasibility, and mechanical characteristics of the EVAx, a novel single-use device designed to disengage, collapse, and constrain suprarenal aortic fixation barbs during open endograft explantati...
R. L. Li, Maxwell C. Braasch, Ali B. Alshawi et al.· Annals of Vascular Surgery· 0 citations
ObjectiveEndovenous laser ablation (EVLA) is standard for superficial venous insufficiency. This retrospective study evaluates the safety profile of "flush" EVLA, assessing whether thermal ablation directly at the saphenofemoral junction (SFJ) increases postoperative thromboembolic complications like deep vein thrombos...