Comprehensive and Comparative Dosimetric Characterization of VMAT and IMRT in Brain Cancer Treatment Planning: Target Coverage, OAR Sparing, Monitor Units, Dose Distribution, Low-Dose Volumes, and Delivery Efficiency
Sep 2026· Natural Resources for Human Health· 0 citations· 32 references
TL;DR
VMAT and IMRT were comparable in terms of target coverage and normal tissue protection, but VMAT needed fewer monitor units and had a significantly lower V20 with numerically lower V5 and V10 although these were not statistically significant.
Abstract
Purpose: A detailed dosimetric comparison is conducted between VMAT and IMRT modalities for brain tumor treatment plans concerning prescription doses of 60, 66, and 70 Gy.
Material and Methods: A total number of forty-three brain tumor patients were selected by means of a retrospective study in the Radiotherapy Department at Baquba Teaching Hospital. Two different treatment plans were made for each patient; one by VMAT, and another by IMRT, for a total of 86 treatment plans. All treatment plans were designed under the same conditions of CT scan images, target contouring, and organ-at-risk constraints.
Results: Overall high PTV coverage was achieved with both techniques and no significant difference was observed in D95 D98 D50 or D2 HI and CI were also comparable, however, higher mean values were obtained for V5 V10 and V20 for the IMRT and a lower number of monitor units were used for treatment delivery in VMAT.
Conclusion: VMAT and IMRT were comparable in terms of target coverage and normal tissue protection, but VMAT needed fewer monitor units and had a significantly lower V20 with numerically lower V5 and V10 although these were not statistically significant.
Objective: The present study aims to compare field-in-field (FIF) radiation therapy, static intensity-modulated radiation therapy (S-IMRT), and dynamic static intensity-modulated radiation therapy (D-IMRT) techniques concerning dosimetric benefits for the treatment of pancreatic cancers. Materials and Methods: Sixteen...
G. Inan, Hamit Başaran, Osman Vefa Gül· Balıkesır Health Sciences Jo...· 0 citations
Purpose To dosimetrically compare multicatheter interstitial high-dose-rate brachytherapy (MIBT) with two volumetric modulated arc therapy (VMAT) techniques, i.e., continuous (cVMAT) and tangential (tVMAT), for accelerated partial breast irradiation (APBI), specifically focusing on organs at risk (OARs) exposure. Mater...
A. Krzystyniak, R. Maksim, Kamil Szczecina et al.· Journal of Contemporary Brac...· 0 citations
OBJECTIVES
To compare the dosimetric performance of HyperArc (HA) and intensity-modulated proton therapy (IMPT) for total scalp irradiation (TSI) in patients with angiosarcoma of the scalp (AS).
METHODS
HA and IMPT treatment plans were retrospectively generated for 27 patients with AS. Prescription doses of 70 and 56...
S. Inui, N. Tomita, T. Takaoka et al.· British Journal of Radiology· 0 citations
A retrospective dosimetric analysis was conducted using treatment planning systems from two radiotherapy centers in Cross River State, Nigeria, equipped with advanced linear accelerators delivering Intensity-Modulated Radiation Therapy (IMRT) and Volumetric Modulated Arc Therapy (VMAT), to investigate the levels of out...
B. Archibong, S. Inyang, Cynthia Onyinyechukwu Igba et al.· International Journal of Hum...· 0 citations
Purpose
We aimed to evaluate the feasibility of using a horizontal port (HP) system for carbon ion radiotherapy (CIRT) in non-small cell lung cancer (NSCLC) by comparing the dosimetric characteristics and dose-averaged linear energy transfer (LETd) with those of a gantry-based plan.
Materials and Methods
Five patient...
Seung-Hyeop Baek, K. Furutani, Seyjoon Park et al.· Radiation Oncology Journal· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.