Skip to content
Open access

Design and Development of a Polycentric Knee Exoskeleton

Aug 2026 · Actuators · Vol 15, pp. 419 · 0 citations · 15 references

TL;DR

The experimental results demonstrate the functional feasibility of the proposed design and provide preliminary evidence of repeatable kinematic behavior during representative lower-limb tasks, and showed that the polycentric configuration better preserved gait symmetry and reduced compensatory adaptations compared with the locked single-axis configuration.

Abstract

This paper presents the design, development, and preliminary proof-of-concept validation of a compact robotic knee exoskeleton for lower-limb assistive application. The proposed system addresses the trade-off between biomechanical compatibility, structural compactness, and reduced mechanical complexity through a lightweight single-degree-of-freedom architecture incorporating a polycentric knee mechanism. The exoskeleton integrates a compact brushless motor unit directly into the wearable structure, combined with a high-ratio transmission system based on a Capstan-driven architecture and a gear-reduction stage, enabling compact actuation. In addition, an embedded sensing system based on magnetic encoders and inertial measurement units was integrated to enable onboard monitoring of joint kinematics during movement execution. Experimental validation was conducted during representative lower-limb tasks, including walking and sit-to-stand movements. Joint kinematics were analyzed through gait-cycle and task-cycle normalization procedures to evaluate the consistency and repeatability of the measured motion. In addition, a comparative gait analysis was performed to assess the biomechanical impact of the proposed polycentric mechanism during walking by comparing natural walking, polycentric-joint walking, and walking with a locked single-axis configuration. The experimental results demonstrate the functional feasibility of the proposed design and provide preliminary evidence of repeatable kinematic behavior during representative lower-limb tasks. Furthermore, the comparative analysis showed that the polycentric configuration better preserved gait symmetry and reduced compensatory adaptations compared with the locked single-axis configuration. These results highlight the potential of reduced-complexity polycentric architectures for developing compact, wearable knee exoskeletons with improved biomechanical compatibility.

Read PDF

Similar papers

Open access Nov 2026

System Design, Integration, and Preliminary Evaluation of a Compensation-Controlled Active Wrist for a Supernumerary Robotic Limb

This paper presents the system-level integration and first experimental evaluation of a 1-DoF active pronation–supination wrist into the SoftHand X, a supernumerary robotic limb developed for upper-limb assistance. Building on an established compensation-control framework, the system combines device-specific kinematic...

Emanuele De Bonis, Maria Serra, A. Franceschini et al. · 0 citations
Open access Sep 2026

A Novel Parallel Exoskeleton for Wrist Rehabilitation: Conceptual Design, Kinematics, and Singularity Analysis

The design and kinematic validation of a novel 3-DOF spherical parallel exoskeleton featuring base-fixed actuators featuring base-fixed actuators featuring exponential rotational matrices is presented, providing systematic derivations of equations in compact form.

Samet Yavuz, S. Himmetoglu · 0 citations
Open access Sep 2026

Design and Performance Evaluation of Unpowered Hip-Assisted Exoskeletons

Human augmentation is an important branch of robotics research aimed at reducing metabolic energy consumption, delaying fatigue, and increasing body speed. However, existing evaluation protocols lack systematic frameworks for unpowered hip devices. This study aims to reduce the energy consumption of human movement with...

Xin-Yao Tang, Xu-Peng Wang, Xin-Ying Xue et al. · 0 citations
Open access Aug 2026

A Hybrid Verification Method for an Actuated Lower-Limb Exoskeleton Based on Mathematical and Simulation Analyses

This study proposes a hybrid method for pre-design verification of the geometric and biomechanical compatibility of experimentally recorded gait trajectories with a lower-limb exoskeleton. The method integrates joint-space kinematic analysis, CAD-based self-collision detection in a Unity digital twin, anatomical hip an...

A. Obukhov, Nikita Mayorov, D. Teselkin et al. · 0 citations

Upper limb exoskeleton supporting exercise for improving range of motion of human joints

Individuals with strokes or musculoskeletal conditions often experience a restricted shoulder range of motion, necessitating rehabilitation that is generally time-consuming, and due to high therapist workloads, patients often need to perform the exercises independently to complete their program. To address this, roboti...

Korawish Thanasit · 0 citations