Skip to content
Open access

Technical validation and feasibility of video particle tracking for low-volume measurement of biliary micro-viscosity after liver transplantation

Oct 2026 · Scientific Reports · Vol 16 · 0 citations · 35 references

Abstract

Reliable quantification of the biophysical properties of human bile requires analytically validated methods and standardized pre-analytical conditions. We hypothesized that biliary micro-viscosity can be quantified in human bile after liver transplantation (LTx) with predefined analytical performance (accuracy \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\le 15\%$$\end{document} deviation from reference, reproducibility CV \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$<10\%$$\end{document}). In this method-development and technical-validation study, we established a method to quantify micro-viscosity in human bile after LTx. Validation using sucrose standards demonstrated high accuracy (\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\le 15\%$$\end{document} deviation from reference), strong linear correlation (\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\textrm{R}^2 = 0.996$$\end{document}), and good reproducibility (CV \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$<10\%$$\end{document}). The method was applied to 21 bile samples from nine patients collected longitudinally after LTx. Mean micro-viscosity was \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$1.58 \pm 0.54~\text {mPa s}$$\end{document} (postoperative day 1), \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$1.94 \pm 0.63~\text {mPa s}$$\end{document} (day 7), and \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$1.44 \pm 0.16~\text {mPa s}$$\end{document} (day 14). Pre-analytical freezing and cooling introduced measurement variability, supporting analysis shortly after collection. These findings demonstrate the analytical performance and practical feasibility of video particle-tracking-based biliary micro-viscosity measurements after LTx. Larger studies combining standardized fresh-sample workflows, biochemical bile characterization, and longitudinal clinical outcome data are required to determine the biological relevance of biliary micro-viscosity and its potential value for future graft modeling.

Read PDF

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.