Sep 2026· European Journal of Obstetrics, Gynecology, and Reproductive Biology· Vol 327, pp.
115444
· 0 citations· 21 references
Medicine
TL;DR
The NRS demonstrated sufficient reliability, construct validity, and interpretability, and partially sufficient responsiveness, for assessing labor pain severity, and these findings support the use of the NRS as a practical and clinically relevant tool for labor pain assessment in both research and clinical settings.
Abstract
Objective
To evaluate the measurement properties of the Numerical Rating Scale for assessing pain severity during labor, including test-retest reliability, measurement error, construct validity, responsiveness, and minimum important difference (MID).
Methods
This longitudinal study was a secondary analysis of a randomized clinical trial involving 200 usual-risk pregnant women in active labor. Participants were randomized to either a pelvic biomechanics intervention protocol using kinesiotherapy with a Swiss ball or usual care. Pain severity was assessed using the 11-point NRS at baseline and after 30, 60, and 90 min. Test-retest reliability was evaluated using the intraclass correlation coefficient (ICCagreement). Measurement error was analyzed using the standard error of measurement (SEMagreement), smallest detectable change (SDCagreement), and limits of agreement (LoA). Construct validity was assessed by comparing pain scores between nulliparous and multiparous women. Responsiveness was evaluated through mixed linear models and standardized effect sizes.
Results
The NRS demonstrated sufficient reliability, with ICCagreement values ranging from 0.713 to 0.963 across assessment intervals. Measurement error progressively decreased over time, with SEMagreement values ranging from 1.03 to 0.23 and SDCagreement values ranging from 2.86 to 0.64. Construct validity was supported, as nulliparous women consistently reported higher pain severity than multiparous women at baseline and follow-up assessments. Responsiveness analysis revealed significant group-by-time interaction effects, indicating distinct pain trajectories between groups. The intervention group showed significantly lower pain scores than the control group at 30, 60, and 90 min (p < 0.001). Between-group differences exceeded the proposed MID threshold of two points at 30 and 60 min. A large effect size was observed for responsiveness (Cohen's d = 1.17).
Conclusion
The NRS demonstrated sufficient reliability, construct validity, and interpretability, and partially sufficient responsiveness, for assessing labor pain severity. The instrument was capable of discriminating between clinically distinct groups and detecting meaningful changes over time during labor. These findings support the use of the NRS as a practical and clinically relevant tool for labor pain assessment in both research and clinical settings.
Background/Objectives The evaluation of treatment effectiveness largely depends on the outcome measures used in the study. Patient-reported outcome measures (PROMs), such as the visual analog scale (VAS), and more objective measures, such as pressure pain thresholds (PPT), are commonly employed to capture pain-sensory...
Rodrigo Martín-San Agustín, Javier Guerra-Armas, Alberto Gadea-Blázquez et al.· Journal of Clinical Medicine· 0 citations
OBJECTIVES
To establish test-retest reliability and minimal detectable change (MDC) values for outcomes in patients with patellar tendinopathy.
DESIGN
Test-retest reliability study.
SETTING
Hospital.
PARTICIPANTS
Thirty participants (29.6 years, 77% males) underwent two test days with a 7-day hiatus.
MAIN OUTCO...
M. H. Hjortshoej, Syed Zahra Gillani, R. B. Svensson et al.· Physical Therapy in Sport· 0 citations
The aim of this study was to determine the test–retest reliability, measurement error and agreement of a pressure biofeedback-based knee proprioceptive force sense (KPFS) assessment in healthy competitive male soccer players. The study employed a methodological test–retest reliability design. A total of 64 male soccer...
Muhammet Özalp· Spor Bilimleri Dergisi Hacet...· 0 citations
Disease-modifying therapies for spinal muscular atrophy (SMA) require standardized follow-up to interpret treatment response. However, short-term changes may reflect measurement variability rather than true clinical change. We therefore assessed the test-retest reliability and relationships of routinely used outc...
Gabriel García-Alcántara, V. Decostre, Marjorie Banos et al.· Orphanet Journal of Rare Dis...· 0 citations
Background: The Modified Tuck Jump Assessment (TJA) is a field-based, video-based tool used to evaluate movement faults relevant to anterior cruciate ligament (ACL) injury mechanisms. Although its reliability has been examined among experienced evaluators, its reliability when scored by novice evaluators remains unclea...
The aim of this study was to investigate whether positive clinical examination findings were associated with selected measures of lower-limb isometric strength or functional performance in physically active adults with groin pain. This was a cross-sectional, observational and exploratory study with blinded outcome asse...
Matheus Oliveira Branco, T. B. Martins, G. V. da Costa et al.· Journal of Orthopaedics and...· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.