Test-bolus peak attenuation for predicting aortic enhancement in coronary computed tomography angiography: an exploratory subgroup analysis

Sep 2026 · Quantitative Imaging in Medicine and Surgery · Vol 16 · 0 citations · 19 references
Medicine

Abstract

Background Adequate intravascular enhancement is essential for accurate coronary computed tomography angiography (CCTA) evaluation; however, conventional empirical contrast protocols often result in significant variability in enhancement because they do not account for individual physiological differences. Test-bolus techniques represent a potential approach for individualized contrast delivery; however, their precise quantitative relationship with final vascular enhancement requires further clarification. This study aimed to investigate the quantitative association between test-bolus peak attenuation and final aortic enhancement (FAE) in CCTA and to describe subgroup variations based on body mass index (BMI) and cardiac output (CO). Methods This single-center retrospective study included 50 patients who underwent CCTA. Test-bolus peak attenuation and FAE were systematically recorded. To evaluate the quantitative association between test-bolus peak attenuation and FAE, univariate linear regression analysis was performed, followed by subgroup analyses stratified by BMI (normal, overweight, or obese) and CO (normal or high). Results Test-bolus peak attenuation was a significant positive predictor of FAE (β=0.924, P<0.001), accounting for 26.1% of the overall variance in FAE. Exploratory subgroup analyses revealed descriptive differences in the strength of this predictive trend across BMI categories. Notably, a stronger predictive trend was observed in obese patients (R2=0.812, P=0.037) than in normal weight (R2=0.310) and overweight (R2=0.247) patients. Conversely, while predictive efficacy remained significant in patients with normal CO (R2=0.288, P=0.001), it was attenuated and statistically non-significant in those with high CO (R2=0.240, P=0.090). Conclusions Test-bolus peak attenuation demonstrated significant potential as a quantitative predictor of aortic enhancement in CCTA, suggesting that test-bolus peak attenuation may be useful in exploring individualized contrast protocols. The descriptive trends observed in the obese subgroup are strictly hypothesis-generating. Exploratory findings suggest that the predictive trend might vary according to BMI and CO. Larger studies are needed to confirm these descriptive observations.

Read PDF

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.