Feasibility of tissue proximity indication during atrial fibrillation rhythm as an indicator of acute pulmonary vein reconnection using variable-loop pulsed field ablation catheter.
Oct 2026· International Journal of Cardiology· Vol 465, pp.
134966
· 0 citations· 18 references
Medicine
TL;DR
TPI assessment during AF rhythm is useful, particularly with version 8.1 and combined with bipolar voltage, despite a slight site-dependency, but the utility of these metrics was slightly site-dependent, with reduced accuracy observed at the roof/floor lines and the anterior region of the left inferior PV and the carina region of right PV.
Abstract
Aims
Although Tissue Proximity Indication(TPI) is considered a useful metric for contact assessment using the variable-loop pulsed field ablation catheter, its significance specifically during atrial fibrillation(AF) rhythm has not been sufficiently evaluated. The purpose of this study was to evaluate the utility of TPI during AF rhythm.
Methods
AND
Results
We enrolled 18 patients(9 patients with CARTO3 version8, 9 patients with version8.1) who underwent pulmonary vein(PV) isolation with or without posterior wall isolation during AF using the system. We investigated the association between acute local PV reconnection and TPI status, bipolar voltage, and impedance at each ablation point during AF rhythm. Local acute reconnection was observed in 155 of 3238 total points(4.4%). In the version 8 group, there was no significant difference in the frequency of acute reconnection based on TPI status. However, in the version 8.1 group, the frequency of reconnection was significantly higher at TPI-negative points compared to TPI-positive points(5.3% versus 3.1%, P = 0.03). Bipolar voltage during AF rhythm was significantly associated with reconnection(R = 0.77, P < 0.001), whereas impedance showed no such association. Furthermore, the combination of high bipolar voltage(≥0.35 mV) and negative TPI status was significantly associated with reconnection regardless of the version(10.7% versus 2.5%, P < 0.001). However, the utility of these metrics was slightly site-dependent, with reduced accuracy observed at the roof/floor lines and the anterior region of the left inferior PV and the carina region of right PV.
Conclusions
TPI assessment during AF rhythm is useful, particularly with version 8.1 and combined with bipolar voltage, despite a slight site-dependency.
Background: Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia. While pulmonary vein isolation (PVI) remains the cornerstone of AF ablation, the optimal method for confirming complete acute isolation remains uncertain. This study evaluated the diagnostic value of pulmonary vein (PV) pacing compare...
L. Katov, Julian Ballweg, Y. Teumer et al.· Journal of Clinical Medicine· 0 citations
BACKGROUND
Pulsed field ablation (PFA) enables rapid and tissue-selective pulmonary vein isolation (PVI). However, the electrophysiological determinants of direct atrial fibrillation (AF) termination during PFA remain unclear.
OBJECTIVE
To investigate the clinical and electrophysiological characteristics associated w...
Eiji Yoshida, Yusuke Sakamoto, Hiroyuki Osanai· Indian Pacing and Electrophy...· 0 citations
In patients with persistent AF, adding PFA-based PWI to PVI did not significantly reduce atrial tachyarrhythmia recurrence lasting 30 seconds or longer compared with PVI alone, and the findings for secondary end points are hypothesis generating and warrant further evaluation in a larger trial.
L. Roten, J. Maurhofer, P. Krisai et al.· Journal of the American Medi...· 5 citations
PFA was delivered mainly in the flower configuration until complete regional coverage of the highlighted areas, avoiding gaps between targeted areas and/or anatomical boundaries. If AF persisted, re-mapping and further ablation of the new highlighted areas could be performed. AF termination was defined as direct restor...
F. Anselme, D. Lațcu, T. Méral et al.· Europace· 0 citations
BACKGROUND
Pulsed field ablation (PFA) is increasingly used for catheter ablation of atrial fibrillation (AF). Limited real-world data exists regarding safety and efficacy of PFA in Australia.
METHOD
We conducted a retrospective analysis of consecutive patients undergoing de novo PFA for paroxysmal or persistent AF a...
Francis J. Ha, Duron Prinsloo, Edwin Xu et al.· Heart, Lung and Circulation· 0 citations
Introduction.
Pulsed field ablation (PFA) is an innovative method for the treatment of atrial fibrillation (AF). The concept of zero-fluoroscopy during ablation procedures is not new. The feasibility and safety of intracardiac echocardiography (ICE)-guided radiofrequency pulmonary vein (PV) isolation have been previ...
A. Revishvili, E. Kropotkin, E. Strebkova· Russian Journal of Cardiolog...· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.