This work reports on subject-adaptive acquisition from measured energy, combining self-supervision with learned acquisition, and amortising the data-consistency weight in generative priors reconstruct accelerated 3D MRI well but pay heavily at deployment.
Abstract
Generative priors reconstruct accelerated 3D MRI well but pay heavily at deployment: tens of network evaluations per volume, and protocol-specific hyperparameter tuning. A third hidden cost is the scanner's fixed sampling pattern. We treat the whole operating point as an input. A 3D MeanFlow patch network (a one-step flow model) is fine-tuned end-to-end through a warm-started, five-iteration differentiable conjugate-gradient projection. A small hypernetwork maps the operating point (data-consistency weight, acceleration, and the Cartesian sampling pattern itself) to the network's per-channel modulation. Three findings follow. (i) Learning the acquisition is worth more than any other operating point: on clinical knee data, the learned mask gains up to +2.34 dB over the protocol's variable-density mask. This gain requires the solver: with a feed-forward reconstructor the same learned mask hurts at 4x (-1.7 dB), but with the data-consistency projection it adds +4.6 dB. (ii) One evaluation is highly effective: it beats a 20-step patch-diffusion prior by up to +3.1 dB on brain and +2.9 dB on knee. Three to five evaluations extend the front to +6 dB while using a quarter of the prior's network calls. (iii) Fully sampled targets are optional: trained self-supervised on a split of acquired samples, the reconstructor matches its supervised twin at 4x on real data. Finally, we report what failed and why: subject-adaptive acquisition from measured energy, combining self-supervision with learned acquisition, and amortising the data-consistency weight.
FlowMoDL robustly converges and strictly outperforms all competitors across all acceleration factors in magnitude SSIM, nRMSE, relative velocity error, and angular error, successfully recovering sharp structural details and temporally coherent velocity fields.
T. Gottwald, Michelle Bruch, M. Hassan et al.· 0 citations
Medical image segmenters often get worse when sites, scanner vendors, or protocols change. Continual test-time adaptation (CTTA) addresses this problem without target labels, but it can be impossible to update a model on a non-stationary stream and can lead to a lot of errors. We examine a more reasonable and meaningfu...
Flow matching methods for imaging inverse problems typically incorporate measurements through network conditioning or guidance during sampling. Neither approach explicitly applies the forward operator within the learned conditional velocity field. We develop a principled measurement-conditional velocity parameterizatio...
Shirin Shoushtari, Edward P. Chandler, Xiao Shi et al.· 0 citations
Regularization losses are the primary driver in this setting, delivering the accuracy gains and almost all of the deformation control for free at inference time, while the affine architecture adds a smaller complementary benefit at acceptable cost.
Segmenting ischemic stroke lesions on T1-weighted (T1w) MRI acquired across different scanners and protocols without intensity standardization is difficult because lesions are subtle and share intensity characteristics with cerebrospinal fluid. Standard deep learning architectures trained across multiple centers platea...
The results show that exploiting paired anatomical correspondence enables diffusion-level LDCT reconstruction with a single step reconstruction, and across all REFM variants, one-step inference consistently provides the highest reconstruction quality.
T. D. Sotta, J. M. Saavedra, Violeta Chang et al.· medRxiv· 0 citations