Oct 2026· Sustainability· Vol 18, pp. 10413· 0 citations
Abstract
EnergyPlus AirflowNetwork (EP-AFN) calculates external node pressure using opening height wind speeds, whereas wind pressure coefficients based on a fixed-reference wind speed (Cpr) are commonly used in building energy simulations. To address this inconsistency, this study used computational fluid dynamics to derive wind pressure coefficients based on opening height wind speeds (Cpl) and implemented them as opening-resolved EP-AFN inputs for two high-rise office buildings. Isolated, Interference, and Urban configurations were examined; the latter two models were compared for airflow and energy performance with and without natural ventilation. Cpl − Cpr differences were more pronounced at lower heights. Under identical Urban conditions, Cpr yielded lower air change rates and heating primary energy consumption than Cpl, with the largest differences on the lower floors. The Interference model showed nearly symmetric Cpl distributions, whereas the Urban model showed irregular distributions. Compared with the Interference model, the Urban model showed lower infiltration and ventilation rates without and with natural ventilation, respectively. The counterfactual comparison showed that the wind-pressure pathway reduced heating primary energy consumption, whereas the shading pathway increased it by reducing solar gains. The net heating response therefore varied with building and floor. These findings highlight the value of an integrated simulation framework with opening-resolved Cpl inputs for evaluating how airflow rates and solar shading shape floor-dependent energy use patterns.
The wind pressure coefficient CP is a key aerodynamic parameter for describing wind-induced pressure fields on building envelopes and is widely used as an input in air flow network (AFN) models. Most CFD validation studies rely on wall-averaged CP or a limited number of center-line sensors, implicitly assuming these re...
Ángel Sánchez-Cruz, E. Ramos, Vladimir A. Reyes-Herrera et al.· Fluids· 0 citations
Natural ventilation in dense urban street canyons is often constrained by low wind speeds, flow recirculation, and turbulent air movement, resulting in poor indoor air quality and thermal comfort. Wind catchers offer a passive ventilation strategy by capturing higher-altitude winds and directing fresh air into building...
V. S. Prakash, D. Prakash, G. Rajamohan et al.· Building Services Engineerin...· 0 citations
Wind energy plays a crucial role in reducing dependence on fossil fuels; however, noise pollution generated by wind turbines remains a major concern for nearby populations and often limits social acceptance. This study presents an experimental assessment of wind turbine noise based on in situ measurement campaigns cond...
Sabrina Slimani, Fatma Zohra Labadlia, Abdelouahab Benretem et al.· Bulletin of Electrical Engin...· 0 citations
<p>Solar panels (SPs) are designed to withstand wind-induced loading, characterised by varying wind speeds and directions, as well as high turbulence. This paper examines force coefficient statistics—mean, standard deviation, 3-s gust and peak values—on an isolated SP model, using data from an experimental...
Kristina Kostadinović-Vranešević, U. Winkelmann, R. Höffer et al.· ASES CONGRESS 2026· 0 citations
Aerodynamic interference among high-rise buildings can substantially alter surface pressures and unsteady wind loads in urban environments. This study investigates the interference effects induced by an interfering building on a principal tall building using a validated large-eddy simulation framework benchmarked again...