Skip to content
Open access

The impact of Lenstar LS 900 optical biometry on intraocular lens power calculation accuracy: A prospective clinical study of 95 Iraqi patients with age-related cataract

Sep 2026 · Babcock University Medical Journal · Vol 9, pp. 348-354 · 0 citations · 18 references

TL;DR

Lenstar LS 900 optical biometry offers high predictive accuracy and efficient workflow in IOL power calculation in patients with age-related cataract in Iraqi patients having cataract surgery.

Abstract

Objective: To evaluate the Lenstar LS 900 optical low-coherence reflectometry biometer for calculating intraocular lens (IOL) power in Iraqi patients having cataract surgery. Methods: This prospective observational study recruited 95 adults (95 eyes) with age-related cataracts between July 2024 and April 2025 where in the method, was Preoperative biometry was performed on all participants with the Lenstar LS 900, so can which measured axial length, corneal curvature, anterior chamber depth, and lens thickness. The SRK/T, Haigis, and Hoffer Q formulas were used to calculate IOL power. A single experienced surgeon carried out phacoemulsification. The main outcome was the mean absolute error (MAE) of predicted and achieved refraction at one-month follow-up. Also found in the section results were the secondary outcomes, which were calculation time, proportion of eyes within the range of ±0.50 dioptres (D) of target refraction, and patient satisfaction. Results: The value of mean MAE was 0.24 ± 0.11 D. Lenstar predictions were accurate (within ±0.50 D of target) in 92.6% (88/95) of eyes, in addition to found value of Mean IOL calculation time was 5.2 +/- 1.1 minutes. Most commonly used formula was the SRK/T formula (52.6%), also the section of Axial length was normal (22.0–24.0 mm) in 52.6% of eyes, while on the other hand, found Eighty-five-point three percent of patients were satisfied with their visual results postoperatively. There were no severe complications. Conclusion: Lenstar LS 900 optical biometry offers high predictive accuracy and efficient workflow in IOL power calculation in patients with age-related cataract.

Read PDF

Similar papers

Open access Sep 2026

Visual outcome following IOL power calculated by SRK/T and Barrett Universal-II formulae: A prospective comparative study

Purpose: To compare the refractive prediction accuracy of the SRK/T and Barrett Universal II intraocular lens (IOL) power-calculation formulas in uncomplicated phacoemulsification cataract surgery. Materials and Methods: This prospective comparative study included 200 eyes of 200 patients undergoing cataract surgery, i...

Pooja Srinivasan, Sozhamadevi Subramanian, S. Elavarasan et al. · 0 citations
Review Open access Oct 2026

Evaluation of Intraocular Lens (IOL) Formulae Utilizing Posterior Corneal Power in Post-Laser Vision Correction (LVC) Eyes

Purpose To evaluate the accuracy of intraocular lens (IOL) power calculation formulae incorporating posterior corneal power vs traditional keratometry in post-laser vision correction (LVC) eyes undergoing cataract surgery. Patients and Methods This multicenter study (7 sites) combined retrospective chart review and pro...

Hasan Alsetri, Mitchell P. Weikert, Nicole R. Fram et al. · 0 citations
Open access Sep 2026

Comparison of Ocular Biometry Agreement and Prediction Error in Eyes with Cataracts

Purpose: To compare ocular biometry measurements obtained using optical low-coherence reflectometry (OLCR), swept-source optical coherence tomography (SS-OCT), and A-scan devices in eyes with cataracts and to evaluate prediction error based on the difference between the predicted refraction and the postoperative spheri...

Xiu-Ying Quan, Geonju Sakong, Kyong-Hwan Cho · 0 citations
Open access Jan 2026

Association Between Lens Thickness and SRK/T Refractive Prediction Error After Cataract Surgery: A Single‐Center Retrospective Cohort Study

Purpose To evaluate the association between lens thickness (LT) and SRK/T refractive prediction error following cataract surgery and to analyze its underlying mechanism. Methods This retrospective cohort study collected data from patients who underwent surgical treatment for age‐related cataracts between January 2025 a...

Tao Liu, Hai-Feng Jiang, Yan-Xia Tong et al. · 0 citations
Open access Sep 2026

Correlation of Preoperative Keratometry and Corneal Astigmatism on Visual Outcomes in Cataract Patients Receiving Non-Toric IOLs

Introduction: Preoperative biometry plays a pivotal role in predicting visual outcomes after cataract surgery. Corneal astigmatism can significantly influence uncorrected visual acuity (UCVA). In clinical settings where only non-toric intraocular lenses (IOLs) are available, understanding the impact of astigmatism beco...

Milzan Murtadha, Sagung Gede Indrawati, Amanda Nur Shinta Pertiwi · 0 citations
Open access Sep 2026

Accuracy of 11 intraocular lens power calculation formulas in short eyes.

PURPOSE To compare the refractive prediction accuracy of 11 intraocular lens (IOL) power calculation formulas in cataract patients with short axial length (AL), and to further evaluate the predictive performance of these formulas across different AL and keratometry (Km) subgroups. METHODS This multicenter retrospecti...

Ting-Ting Pan, Xue Ding, Wei-Kang Bi et al. · 0 citations