Oct 2026· Journal of Structural Engineering· Vol 152· 0 citations· 52 references
Abstract
With growing demand on low-carbon and fire-safe building solutions, timber–concrete composite (TCC) floors have emerged as a sustainable and efficient alternative. This paper provides a critical review of the fire performance of slab-type TCC floors, with an emphasis on studies reported in the past five years, including 25 full-scale furnace tests. Results show that cross laminated timber (CLT) concrete floors are prone to char fall-off, leading to sharp inner temperature rises and highly variable fire resistance (30–214 min), mainly influenced by load ratio, lamella thickness, and connection type. The fire resistance of slabs generally exceeded 90 min under service loads, and higher load ratios caused earlier failure. By contrast, nail-laminated timber– and laminated veneer lumber–concrete systems exhibited stable charring and consistently higher resistance (
>
190
min
). Emerging simulation approaches that model char fall-off and temperature-dependent connector degradation show improved agreement during extended fires, though broader validation is still needed. Simplified analytical methods, such as the
γ
-method, provide useful estimates but require calibration across load levels. Future research should refine delamination modeling, incorporate temperature-dependent connector behavior, and recalibrate analytical methods using full-scale data to ensure reliable fire design of TCC floors.
Timber–concrete composite (TCC) floor systems offer an efficient hybrid solution that leverages the high stiffness and strength capacity of concrete with the lightweight, renewable characteristics of mass timber. Although extensive research has been conducted on simply supported TCC members subjected to positive bend...
Monther Nayfeh, Pouria Bahmani· Journal of Structural Engine...· 0 citations
In pursuit of sustainable construction aligned with the European Green Deal and Taxonomy Regulation, this study investigated the structural performance of a steel–timber–concrete composite (STCC) shallow floor beam as a low‐carbon alternative to traditional steel– concrete systems. The cross‐laminated timber (CLT) used...
Adil Ahmad, J. Demonceau, Jie Yang et al.· ce/papers· 0 citations
Shallow bins, commonly used for storing material, are typically designed for ambient conditions, overlooking their response under elevated temperatures, such as during fire outbreaks. To illustrate the impact of elevated temperatures on structural performance and signify the necessity of some protection measures, this...