Design and Psychophysical Calibration of a Multimodal Pneumatic–Vibrotactile Wearable Interface for Cutaneous Feedback
Abstract
In order for wearable haptic feedback devices to be reliable, a critical trade-off between portability and information density is often unavoidable. While wearable interfaces offer improved operator mobility compared to grounded devices, they often lack the bandwidth to render both sustained physical properties (in this work, informational stiffness) and rapid transient cues (e.g., collision events) effectively. This paper presents the design and psychophysical calibration of a novel multimodal wearable interface intended for scenarios requiring high situational awareness. The system combines hybrid soft-rigid pneumatic indentation with vibrotactile feedback. To characterize the interactions between these modalities, a robust rendering architecture is introduced, consisting of: a piecewise linear-saturated mapping for informational stiffness modulation based on a monitored system state, and an affine intensity compensation model to prevent masking of high-priority events. The actuator’s electromechanical dynamics were first characterized on the bench, and a preliminary user study with twelve participants then provided evidence of distinct perceptual regions for pneumatic indentation, confirmed and quantified the vibrotactile masking effect, and identified a stiffness discrimination threshold. These results serve as a device-specific calibration for the proposed control framework.