Dual-sensor correlation for wideband HFCT partial discharge detection and interference suppression in transformers

2026 · Research on Engineering Structures and Materials · 0 citations

Abstract

On-site partial discharge (PD) detection of power transformers is challenged by strong electromagnetic interferences, including converter pulsation, corona, and power-side harmonics, whose spectra overlap with PD signals. A dual-channel synchronous detection system based on self-developed wideband high-frequency current transformer (HFCT) sensors was developed. The HFCT had an operating band of 3–50 MHz and an average transfer impedance of 16 mV/mA, whereas the signal-conditioning system covered 150 kHz–60 MHz. A 14-bit acquisition unit sampled both channels at 250 MSps using a common clock, corresponding to a sampling interval of 4 ns. Satellite timing synchronized distributed acquisition units with an accuracy better than 100 ns. A dual-sensor correlation discrimination method was proposed using time-of-arrival difference, polarity sign, and amplitude transfer ratio as weighted decision parameters in the propagation-path domain. Experiments on a 220 kV/2 MVA single-phase transformer simulation platform using a dataset of 2,800 frames, comprising 2,400 defect–interference combination frames, 240 background-noise frames, and 160 calibration-signal frames, achieved 91.3% recognition accuracy, 14.2 dB SNR improvement, 37.8 ms processing time per 4,096-sample event window, and a 2.4% detection blind zone. The event-level evaluation included 800 PD events and 1,600 interference events extracted from the defect–interference combination frames. Compared with wavelet thresholding, EEMD, and adaptive SVD, the proposed method improved accuracy by 3.7–8.6 percentage points, with recalculated electrical-localization errors ranging from 0.21 to 0.40 m, while the minimum identifiable apparent charge for air-gap discharge was approximately 5.8 pC. The method provides an effective solution for reliable on-site PD detection under complex electromagnetic environments.

Read PDF

Similar papers

Open access 2026

Pulse-Type interference suppression based on an improved wavelet threshold for wideband partial discharge detection in transformers

Pulse-type interference at high-voltage (HV) and ultra-high voltage (UHV) transformer sites severely limits the effectiveness of partial discharge (PD) detection, as conventional pulse current measurement below 1 MHz leaves 12-pulse ripple, corona, and electronic switching pulses overlapping with genuine PD signals in...

Guang-Hu Xu, Qing-Chuan Zhang, Gang Chen et al. · 0 citations
Aug 2026

Monopole Coil Antenna for Partial Discharge Detection in High-Voltage Equipment

This study proposes a novel monopole coil antenna for detecting partial discharge (PD) in high-voltage (HV) and medium-voltage (MV) equipment. The proposed antenna addresses the critical challenge of distinguishing PD-generated signals from external electromagnetic interference (EMI). The integration of a low-impedance...

Yusuke Yamakaji, Takahiro Mizuguchi, Moe Kitano et al. · 0 citations
Open access 2026

TEV Signal Analysis in Power Transformers: Effects of PD Location and Resonance Modes

Detection of partial discharge (PD) in power transformers is crucial since it indicates early-stage insulation degradation that may lead to system failure. The transient earth voltage (TEV) sensor offers a non-intrusive method for measuring PD during online transformer operation. In this paper, the application of the T...

Mahdi Abbasi, M. Lachance, Éric David · 0 citations
2026

A High-Precision Noninvasive DC Voltage Measurement Method Based on a Near-Field Differential Array

Noninvasive voltage measurement is crucial for the condition monitoring and fault diagnosis of ultrahigh-voltage direct current (UHVDC) systems. Existing electric-field inversion methods often suffer from sensitivity to sensor placement and vulnerability to common-mode interference, limiting their practical accuracy. T...

Ze-Hao Li, Xiao-Ni Wang, Zi-Jian He et al. · 0 citations
Conference Sep 2026

Current Measurement and Synchronous Rectification at MHz+ Switching Frequency

To achieve high-efficiency operation in high-frequency GaN-based resonant DC-DC converters, precise Synchronous Rectification (SR) plays an important role. However, in the MHz switching frequency range, reliable and accurate zero-detection becomes significantly challenging. In this frequency range, conventional sensing...

Mohammad Mehdi Kashani, Oleksandr Husev, Daniel Sánchez et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.