Seismic Assessment and Strengthening of Historical Masonry Structures: Ferdowsi High School, Tabriz, Iran
Abstract
In this study, the seismic vulnerability of the Ferdowsi School building in Tabriz is investigated. The research began with comprehensive fieldwork, during which exploratory surveys and in-depth technical inspections of all structural components were performed. Experimental testing of prismatic masonry specimens was carried out to evaluate their mechanical characteristics, and the resulting properties were then incorporated as input parameters into the numerical model. The seismic vulnerability assessment was then carried out using nonlinear static (pushover) analysis, applying a lateral load pattern proportional to the first vibration mode of the structure. For numerical simulation, the building was modeled in the ABAQUS finite element software using the macro-modeling technique. The results of the nonlinear static analysis indicated that the building does not possess sufficient load-bearing capacity at the target displacement. Damage was primarily concentrated in the form of cracking in the masonry walls as well as in the dome-shaped sections of the roof, requiring the implementation of a seismic retrofitting scheme to enhance the structure’s seismic performance. To rehabilitate the structure, horizontal and vertical reinforced concrete beams were introduced as confining elements for the masonry walls and subsequently applied in the strengthening project. Furthermore, due to the presence of a domed roof at the first-floor level, it was strengthened using FRP composite materials to enhance tensile capacity and ductility. At the second-floor level, where the roof structure is made of timber elements, a steel cable system was employed to improve its strength and diaphragm action. As for the third-floor timber truss roof, the connections were upgraded and reinforced to provide reliable force transmission and to maintain the overall integrity of the structural system. Following the implementation of the retrofitting measures, the structural model was re-analyzed using nonlinear static analysis. The results demonstrated that the proposed strengthening scheme successfully increased the structural capacity up to the target displacement level and satisfied the intended performance requirements. In the final section of the paper, the implementation details of the retrofitting interventions, as well as the practical experiences gained during the implementation process, are presented and discussed.