Skip to content
Open access

Toward a computationally efficient numerical approach to simulate the left atrial appendage occlusion in patient-specific anatomies.

Sep 2026 · Computer Methods and Programs in Biomedicine · Vol 287, pp. 109652 · 1 citation · 48 references
Medicine

TL;DR

The proposed pipeline enables scenario-based, patient-specific LAAO simulation and substantially reduces computational cost while preserving accuracy, whereas neglecting hooks (BFM) is not acceptable.

Abstract

Background

AND

Objectives

Left atrial appendage occlusion (LAAO) is increasingly used to prevent stroke in atrial fibrillation, but device selection and positioning remain challenging due to complex, patient-specific anatomy and uncertain wall mechanics. Finite element (FE) simulations could support pre-interventional planning, provided they are both accurate and computationally efficient. This study extends a previously validated Watchman FLX FE model to patient-specific anatomies and evaluates model simplifications to reduce runtime without compromising clinically relevant predictions.

Methods

A detailed Watchman FLX model (Complete Model, CM) and two simplified variants (No Fabric Model, NFM, in which the proximal fabric membrane is omitted; Bare Frame Model, BFM, consisting solely of the metallic frame and excluding both the fabric and the anchoring hooks) were implemented in Abaqus/Explicit. Three patient-specific LA-LAA anatomies were reconstructed from CT. For each anatomy, four scenarios were simulated (optimal/suboptimal catheter positioning × low/high wall stiffness), for a total of 12 scenarios and 36 simulations. Deployment, anchoring and release were modeled. Outcomes included LAA sealing (gap classification), device protrusion into the LA, intrusion into the LAA, and CPU time.

Results

With the CM, procedural outcome strongly depended on positioning and wall stiffness, even for a fixed device size. For all anatomies, at least one scenario achieved complete sealing and acceptable alignment. The NFM reproduced CM gap classification in all cases and intrusion/protrusion within ±1 mm in 10/12 scenarios, correctly identifying poor outcomes in the remaining two. The BFM showed unstable deployment in 2/12 scenarios and mispredicted gaps and protrusion in others. Average runtimes were 5.6 h (CM), 3.8 h (NFM), and 3.2 h (BFM).

Conclusions

The proposed pipeline enables scenario-based, patient-specific LAAO simulation. Neglecting the fabric (NFM) substantially reduces computational cost while preserving accuracy, whereas neglecting hooks (BFM) is not acceptable.

Read PDF

Similar papers

Review Open access Sep 2026

Cardiac CT Roadmap for Left Atrial Appendage Occlusion: From Planning to Strategy to Follow-Up

Cardiac computed tomography (CCT) has emerged as a central imaging modality in the workflow for left atrial appendage occlusion (LAAO), as accurate anatomical assessment is vital for successful intervention. CCT provides superior three-dimensional (3D) anatomical detail and isotropic spatial resolution compared to trad...

A. Meloni, K. Capellini, B. Fanni et al. · 0 citations
Open access Sep 2026

Volume-constrained wall motion alters left atrial appendage hemodynamic descriptors: a CFD sensitivity study

Rigid-wall left atrium (LA) and left atrial appendage (LAA) computational fluid dynamics models are practical but suppress deformation-driven transport, whereas image-derived wall motion is data- and processing-intensive. We evaluated whether a reduced-order, volume-constrained wall-motion prescription changes computed...

J. Silva, Julio Gallinaro Maranho, Rodrigo L. Amaral · 0 citations
Preprint Oct 2026

From Simulation to Suture Lines: Computational Fluid Dynamic Simulation-Guided Baffle Construction for Complex Biventricular Repair

Biventricular repair is favored for children with complex double-outlet right ventricle (DORV) to eliminate the long-term morbidity of single ventricle physiology. However, creating a baffle that maintains adequate cross-sectional area while limiting incursion on the tricuspid valve apparatus is challenging in a distor...

Alexander K. Reed, Elena Sabdy Martinez, Alexander D. Kaiser et al. · 0 citations
Open access Oct 2026

Patient-specific hemodynamic evaluation of fenestrated physician-modified endografts in complex abdominal aortic aneurysms

Physician-modified endografts (PMEGs) are increasingly used for complex abdominal aortic aneurysms (AAA), but the patient-specific flow consequences of the geometric reconstruction are not well quantified. This study evaluated PMEG-associated changes in hemodynamic and wall-mechanical surrogate markers. Eigh...

Xiao-Long Du, Shi-Chen Jiang, Hong-Yue Zhang et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.