Skip to content
Conference Open access

Research on current harmonic suppression strategy of permanent magnet synchronous motor based on improved PIR control

Sep 2026 · Journal of Physics, Conference Series · Vol 3326 · 0 citations · 2 references
Physics

Abstract

Nonlinear factors such as inverter dead time and power device voltage drop generate prominent 5th and 7th low-order harmonics in PMSM stator currents, which lead to severe torque ripple and distorted current waveforms. Traditional proportional-integral resonant (PIR) controllers adopt standard bilinear transformation for digital discretization, which introduces inherent resonant frequency drift under wide-speed operation and deteriorates harmonic suppression precision. To address this issue, this paper constructs a PI-resonant composite control strategy in the synchronous dq rotating frame. A pre-corrected bilinear transformation is proposed to optimize the discretization process of resonant units, which fully compensates for mapping frequency deviation and eliminates resonance point mismatch. Simulation results at low and rated high speeds verify the effectiveness of the proposed method. It accurately suppresses 5th/7th characteristic harmonics and improves current sinusoidal quality, while enhancing control precision, dynamic response and full-speed adaptability with guaranteed system stability. Featuring a simple structure and straightforward parameter tuning, the presented algorithm provides a feasible engineering solution for wide-range high-precision low-harmonic PMSM drives.

Read PDF