Skip to content
Review

Robotic cholecystectomy using da Vinci SP, single-site, and multiport systems: a systematic review and comparative meta-analysis

Oct 2026 · Journal of Robotic Surgery · Vol 20 · 0 citations · 32 references
Medicine

TL;DR

The evidence is very uncertain about differences in total operative and console time between da Vinci SP and Single-Site cholecystectomy, and an overall operative-time advantage or comparative safety equivalence has not been established.

View source

Similar papers

Review Oct 2026

Feasibility and perioperative outcomes of Senhance-assisted robotic cholecystectomy: a single-arm meta-analysis

The findings of this single-arm meta-analysis indicate that Senhance-assisted robotic cholecystectomy is both safe and feasible, demonstrating a high surgical success rate, acceptable operative times, and a short postoperative hospital stay.

Ye Tao, Wen-Tao Lei, Xin-Min Niu et al. · 0 citations
Clinical trial Open access Aug 2026

Efficacy and Safety Analysis of Single-Port Robotic Assisted Cholecystectomy Using a Novel Surgical Platform: A Bicentre, Single-Arm, Prospective Phase II Clinical Study.

The novel single-port robot demonstrated feasibility and safety in cholecystectomy with effective triangulation, controlled operative time and reduced trauma.

Chao Jing, Kun Liu, Guo-Wei Zhang et al. · 0 citations
Review Sep 2026

Single-Port Robotic Posterior Retroperitoneoscopic Adrenalectomy (SPRe-Ad): A GelPOINT Mini-Enabled Floating-Docking Technique.

PURPOSE To describe a GelPOINT Mini-enabled access configuration for single-port posterior retroperitoneoscopic adrenalectomy (SPRe-Ad) using the da Vinci SP system, with emphasis on floating docking, posterior abdominal-wall tenting, and early perioperative outcomes. MATERIALS AND METHODS Two consecutive adults unde...

M. Raffaelli, P. Procopio, A. Laurino et al. · 0 citations
Review Sep 2026

Single-Port Versus Multiport Robotic Colorectal Surgery: A Systematic Review and Meta-Analysis.

BACKGROUND Single-port (SP) robotic surgery has emerged as a reduced-access alternative to conventional multiport (MP) robotic colorectal surgery. However, its comparative perioperative benefits remain uncertain. This systematic review and meta-analysis compared outcomes between SP and MP robotic colorectal surgery....

Vitória Maia Corrêa, Fernanda de Moraes Nava, F. Kelher et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.