Sep 2026· Translational Andrology and Urology· Vol 15, pp. 325-325· 0 citations· 26 references
Medicine
TL;DR
KD-SR-01-assisted ureteral reimplantation is safe and feasible, with perioperative safety and mid-term clinical outcomes comparable to those of da Vinci-assisted surgery, and data suggest that the platform may be a feasible alternative in selected reconstructive cases.
Abstract
Background Ureteral reimplantation is central to distal ureteral reconstruction, but evidence comparing emerging robotic platforms with the established da Vinci system remains limited. We compared the perioperative safety and mid-term outcomes of KangDuo Surgical Robot-01 (KD-SR-01)-assisted and da Vinci-assisted ureteral reimplantation. Methods We retrospectively analyzed 153 patients who underwent robot-assisted ureteral reimplantation between January 2024 and December 2025. Platform allocation was nonrandom and reflected patient choice after standardized counseling. The primary outcome was mid-term surgical failure, defined as persistent symptoms or radiographic obstruction requiring continued urinary drainage or further intervention; secondary outcomes were operative time, estimated blood loss, postoperative hospital stay, postoperative renal function, and complications. The primary analysis was multivariable regression adjusted for baseline differences in case complexity, with Firth penalized models used for the rare binary outcomes. Propensity score matching was retained as a sensitivity analysis. Results Before adjustment, the da Vinci group had longer strictures [5.0 (3.0–10.0) vs. 4.0 (3.0–5.0) cm; P=0.01] and more previous failed reconstructions (31.4% vs. 13.7%; P=0.03). All procedures were successfully completed without conversion. KD-SR-01 was associated with a longer operative time [adjusted difference, 13.91 minutes; 95% confidence interval (CI): 1.94–25.88; P=0.02]. No significant differences were observed in estimated blood loss, postoperative hospital stay, postoperative serum creatinine, or postoperative estimated glomerular filtration rate. Complications occurred in 3/51 (5.9%) KD-SR-01 and 7/102 (6.9%) da Vinci cases (adjusted odds ratio, 0.91; 95% CI: 0.20–3.49); surgical failure occurred in 1/51 (2.0%) and 2/102 (2.0%), respectively (adjusted odds ratio, 1.20; 95% CI: 0.09–10.93). Results were consistent in the propensity score-matched sensitivity analysis. Conclusions KD-SR-01-assisted ureteral reimplantation is safe and feasible, with perioperative safety and mid-term clinical outcomes comparable to those of da Vinci-assisted surgery. Although the longer operative time with KD-SR-01 may reflect the surgeon's early learning curve and a more methodical operative workflow, these data suggest that the platform may be a feasible alternative in selected reconstructive cases.
RAARP had shorter core but longer total operative time because of robotic docking, and Operative times decreased across consecutive RAARP cases, although no proficiency threshold was estimated.
Zi-Teng Yang, Ze-Bing Zheng, Tao Zhan et al.· Surgical Endoscopy· 0 citations
Single-port and multiport robot-assisted laparoscopic pyeloplasty demonstrated comparable perioperative outcomes and high surgical success in children with ureteropelvic junction obstruction and the single-port approach may provide better cosmetic satisfaction, although the available evidence remains limited.
Muhammad Nadhif Jovaldy, Muhammad Aditya Pasya, Ahmad Furqon Abdusyakur et al.· Adolescência e Saúde· 0 citations
Objective: Robotic reconstructive urology is well described on the da Vinci system but rarely on other platforms, and seldom from low- and middle-income countries. We report an initial experience with the Edge MP1000 and Toumai multiport systems at a national referral center.
Methods: We retrospectively reviewed 7 con...
A. A. Soeroto, M. A. Maulana, S. Lionardi et al.· Urology Research and Practic...· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.