Skip to content

Advancing high contrast interferometry: new metrology system for the VLTI

Aug 2026 · Astronomical Telescopes + Instrumentation · Vol 14148, pp. 141481R - 141481R-16 · 0 citations · 10 references
Engineering

Abstract

Future high contrast interferometric observations with the Very Large Telescope Interferometer (VLTI) require nanometer level control of optical path variations to preserve fringe stability and maximize sensitivity. Within the framework of the PLANETES project, a dedicated laser metrology system is being developed to monitor optical path variations over the full interferometric beam train, complementing the dual field observing strategy by providing real time, absolute optical path difference measurements between the VLTI laboratory and the telescope level. The metrology system distributes a 1064nm laser source through optical fibers to a network of Mach-Zehnder interferometers, enabling continuous monitoring of vibrations affecting the optical train. This paper presents the metrology concept and optical architecture, along with initial laboratory performance results from the metrology testbed. Measurements demonstrate accurate retrieval of controlled optical path perturbations and broadband vibration signals, validating the proposed architecture for dynamic optical path sensing.

View source

Similar papers

Open access Sep 2026

A compact quadrangular optical metrology testbed for interferometric readout and dynamic phase tracking

Ground-based verification of optical metrology technologies is essential for future space-borne gravitational-wave observatories. Previous studies have demonstrated ultra-stable optical benches for phasemeter verification, optical pathlength stability characterization, and laser transponder investigations. In this work...

Meng-Heng Li, Xiao-Ling Liang, Zi-Ji Chen et al. · 0 citations
Conference Sep 2026

Design of force-thermal stability for a common-path infrared interferometric measurement system

High-resolution spectrometers hold irreplaceable value in cutting-edge fields such as deep-space exploration, Earth remote sensing, and meteorological observation, serving as a core payload for detailed astrophysical studies and global environmental monitoring. In a spectrometer system, the diffraction grating is the k...

Bin Liu, Shou-Xin Guan, Fei-Chen Wang et al. · 0 citations
Conference Open access 2026

High-density interferometric wide-area measurement of grating pitch and homogeneity

High-accuracy characterization of optical grating pitch is increasingly important for the quality control of diffractive optical elements, particularly in the emerging augmented reality optics. To address the limitations of conventional measurement methods, such as AFM and diffractometry, we present a snap-shot interfe...

Aleksi Mattila, A. Lassila · 0 citations
Oct 2026

On-site optical wavefront testing and control for the AIMS solar telescope

The Accurate Infrared Magnetic Measurement System (AIMS) solar telescope is the world’s frst mid-infrared observational system dedicated to high precision measurements of solar magnetic felds and independently developed in China. The large number of optical components, multiple intermediate focal planes, and the long...

K. E., Jian-Ke Zhao, Yu-Liang Shen et al. · 0 citations
Open access Oct 2026

Absolute measuring interferometric high-speed profilometer using wavelength modulation at ultrasonic frequencies

We present a laser interferometric approach for absolute distance measurements based on current-modulated laser diodes. The proposed system employs a point-wise measuring interferometer operating with two lasers of slightly different wavelengths in the telecommunications spectral range. By exploiting the modulated in...

Tim Eckhardt, Sebastian Hagemeier, Yi-Jian Zou et al. · 0 citations
Open access Oct 2026

Fundamental optical metrology with cold H2 molecules within the COMOMET project

High-finesse optical cavity spectrometers are powerful tools for precision molecular spectroscopy and fundamental metrology. When combined with cryogenic environments, these systems gain additional advantages important for high-precision measurements, such as reduced Doppler broadening of spectral lines, narrower Boltz...

M. Chomski, P. Głowacki, Aleksandra Malinowska et al. · 0 citations