Oct 2026· Journal of Stomatology Oral and Maxillofacial Surgery· Vol 127, pp.
103031
· 0 citations· 26 references
Medicine
TL;DR
Virtual surgery planning demonstrated clinically acceptable accuracy for maxillary positioning in midsagittal plane, however, mandibular vertical repositioning did not meet predefined equivalence criteria in the selected angular parameters.
Abstract
Background
Three-dimensional virtual planning is an established method in orthognathic surgery. While numerous studies support its accuracy and precision, considerable variability in its extent has been reported.
Aim
OF THE STUDY
This study assessed whether postoperative cephalometric outcomes corresponded to planned values within predefined clinically acceptable limits.
MATERIAL AND
Methods
This retrospective cohort study included 53 patients with dentofacial deformities who underwent bilateral sagittal split osteotomy with (n=29) or without Le Fort I osteotomy (n=24). The dataset comprised preoperative computed tomography scans of the skull and pre- and postoperative lateral cephalometric radiographs. Initially, two- and three-dimensional preoperative cephalometric analyses were compared to quantify measurement errors. Subsequently, angular parameters planned during three-dimensional virtual surgical planning were compared with those obtained postoperatively via two-dimensional cephalometric analysis. Equivalence was assessed using predefined clinical limits of ±2° with two one-sided tests.
Results
Preoperatively, no statistically significant angular deviations between 2D and 3D cephalometry were identified (p>0.05). Postoperatively, five out of seven angular parameters met the criterion for equivalence, with mean deviations within ±2°. For MnP-NS and MxP-MnP, mean deviations exceeding 2° were shown (2.054 and 2.015, respectively).
Conclusion
Virtual surgery planning demonstrated clinically acceptable accuracy for maxillary positioning in midsagittal plane. However, mandibular vertical repositioning did not meet predefined equivalence criteria in the selected angular parameters. For unbiased postoperative evaluation of mandibular positioning, lateral cephalometric radiographs should be obtained after resolution of early confounding factors and represent a cost-effective, low-radiation alternative to three-dimensional imaging for sagittal and vertical assessment.
Customized surgical guides may improve the accuracy of minimally invasive orthognathic surgery, particularly in facilitating the transfer of three-dimensional virtual surgical planning (3D-VSP) to the operative setting. This retrospective comparative cohort study included patients undergoing bimaxillary surgery with si...
G. De Fazio, A. Diez-Fraile, T. Faro et al.· International Journal of Ora...· 0 citations
OBJECTIVES
To prospectively evaluate the transversal surgical accuracy and one-year stability of segmented Le Fort I osteotomy using a validated three-dimensional (3D) voxel-based assessment protocol.
METHODS
In this prospective single-center study, patients undergoing two-piece or three-piece segmented Le Fort I ost...
O. da Costa, Eman Shaheen, Pourkarim Ali Reza et al.· Journal of Stomatology Oral...· 0 citations
Background: Segmental Le Fort I osteotomy combined with interdental alveolar bone reduction is a technically challenging procedure, and the accuracy of patient-specific implants (PSIs) in this setting has not been well established. This study aimed to assess the three-dimensional (3D) repositioning accuracy and safety...
Xin-Yu Xu, Ling Wu, Zi-Li Li et al.· Journal of Clinical Medicine· 0 citations
Preoperative planning is crucial in orthognathic surgery, addressing both functional and aesthetic aspects in young adults. The current state-of-the-art still relies on fully manual virtual surgery planning despite the availability of detailed three-dimensional imaging. A prototype system for orthognathic surgery plann...
F. Bouffleur, C. Bauer, R. Kühle et al.· International Journal of Ora...· 0 citations
BACKGROUND
Dental occlusion is critical in orthognathic planning. Although manual articulation of casts was considered the reference standard, digital workflows are adopted.
PURPOSE
To assess linear and angular discrepancies between virtual occlusion (VO) and manual reference occlusion (MrO) to determine VO accuracy....
Y. Gugliotta, G. Gerbino, F. Marcolin et al.· Journal of oral and maxillof...· 0 citations
Abstract This study evaluated three-dimensional (3D) soft tissue changes and their correlations with hard tissue movements after combined bimaxillary orthognathic surgery. A retrospective analysis was performed using cone-beam computed tomography scans obtained from 22 adults before surgery (T1) and at least 6 months a...
C. O. Lisboa, S. Mota-Júnior, J. T. Carneiro et al.· Brazilian Oral Research· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.