SonoCorpus, an open resource unifying 456,963 images and 1,626,085 expert masks from 53 public datasets spanning 24 clinical applications and 17 countries, and SonoBase, an interactive segmentation foundation model pretrained on it are presented, locating the advantage in ultrasound-specific pretraining rather than any single architecture.
Abstract
Ultrasound is the most widely deployed imaging modality worldwide, yet clinical AI remains fragmented into narrow single-task models that fail when device, operator, or anatomy changes. Here we present SonoCorpus, an open resource unifying 456,963 images and 1,626,085 expert masks from 53 public datasets spanning 24 clinical applications and 17 countries, and SonoBase, an interactive segmentation foundation model pretrained on it. Across fifteen evaluation datasets introducing new organs, devices, operators, and geographies, SonoBase outperforms SAM2, MedSAM2, and the concept-promptable MedSAM3 on every dataset and matches per-dataset specialist models trained on the same data; on fully external data it exceeds the accuracy these baselines achieve on their own in-distribution benchmarks. Ejection fraction derived from its segmentations falls within inter-observer variability (6.63\% error), with fewer misclassifications at the defibrillator-candidacy threshold than either promptable baseline (13\% versus 18--42\%); fetal head-circumference (1.81~mm) and gestational-age (1.2 days) errors fall below inter-observer variability. Where a baseline fails outright, one in four test cases, SonoBase recovers a usable segmentation in 81\% of them, including on handheld probes operated by minimally trained users in two low- and middle-income countries (Sierra Leone and Tanzania). Five labeled examples can help the model adapt to a new setting, and the identical training protocol transfers well to newer models such as SAM3, locating the advantage in ultrasound-specific pretraining rather than any single architecture. To ensure reproducibility and enable the community to build on SonoBase as a platform, we release all checkpoints, optimizer states, data-split indices, deduplication hashes, and starter code at https://github.com/AlfredQin/sonobase.
The effect of real-world distribution shifts on three-dimensional AI models for lung nodule analysis on CT and MedStyle-3DG, an open-source 3D vision-language framework for domain generalization, are quantified and evaluated.
B. Bercean, Rafael Medelean, A. Tenescu et al.· Journal of imaging informati...· 0 citations
Interactive segmentation of 3D medical images supports quantitative analysis of anatomical structures and disease while allowing users to specify and refine their targets. Despite substantial progress by nnInteractive and VISTA3D, reliable segmentation across diverse clinical targets remains challenging, particularly f...
Ping-Qiu Gong, Shi-Yuan Su, Fan-Dong Zhang et al.· 0 citations
Accurate segmentation of breast lesions in ultrasound remains challenging due to limited data and acquisition variability.
To quantify how common augmentation operators and their combinations affect cross-dataset generalization of a standard U-Net for breast lesion segmentation.
We trained on the...
V. Rahmawati, Syahril Siregar· Imaging· 0 citations
It is shown that conventional in-distribution evaluation can obscure clinically important generalization failures and support explicit cross-dataset testing as a key component of CHD segmentation evaluation, and conventional in-distribution evaluation can obscure clinically important generalization failures.
Aniketh Vijesh, Shrisharanyan Vasu, Abhijit Ramesh et al.· 0 citations
Medical image segmentation plays a critical role in computer-assisted diagnosis, treatment planning, surgical navigation, and quantitative medical image analysis. Among deep learning-based segmentation architectures, U-Net has become one of the most influential frameworks because of its encoder–decoder structure and sk...
Tian-Hui Wu, Shamsher Ullah, Bo-Chen Yu et al.· Journal of Imaging· 0 citations
A targeted source-inclusion sensitivity analysis indicates model- and cohort-dependent sensitivity to training-pool composition, rather than a universal benefit from adding data or a universally preferred configuration, in breast ultrasound segmentation.
Lin Ma· Medical Engineering and Phys...· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.