BULLKID is a cryogenic solid-state detector based on an array of silicon dice equipped with Kinetic Inductance Detectors (KIDs) for low-mass dark matter searches and coherent elastic neutrino-nucleus scattering. Energy calibration can be performed using optical LED photon bursts, which are absorbed within the first few hundred nanometers of the substrate. An energy calibration using a $^{241}$Am gamma-ray source revealed a $<10\%$ discrepancy with the LED calibration. A recent study by Matava and Williams suggested that phonon statistics and phonon collection varying with the interaction position could explain such a discrepancy. This work evaluates the impact of these effects on the calibration of the BULLKID detector, demonstrating they both have a negligible effect. We clarify the results obtained during the $^{241}$Am calibration regarding the origin of the observed discrepancy.
We report Geant4-based simulations of cosmic-ray muon backgrounds in models reproducing the geometries of the five-arm and six-arm e+e- pair spectrometers operated by the Atomki group at Debrecen. Full detector geometries are implemented for both setups, including position-sensitive detectors and plastic scintillators....
H. Benmansour, G. Boca, G. Cavoto et al.· 1 citation
Photon calibration (Pcal) systems are essential for accurately reconstructing gravitational-wave strain in laser interferometric detectors. In the KAGRA Pcal system, the laser power applied to the end test mass is measured using integrating-sphere power sensors. During the first part of the fourth observing run (O4a),...
Silicon PhotoMultipliers (SiPMs) are among the standard devices for light detection in scintillator detectors. Some detector designs require these devices to be placed in radioactive areas or directly exposed to particle beams. Specifically, the damage from exposure to low-momentum muons is particularly important, as t...
Riccardo Rossini, Sayani Biswas, Adrian D. Hillier et al.· 0 citations
Intrinsic sensitivity is a key parameter for vacuum Compton detectors (VCDs), enabling the quantitative analysis of pulsed γ-radiation fields. Since VCDs are insensitive to the emitted electron energy, traditional calibration of intrinsic sensitivity has generally neglected the contribution of low-energy electrons. In...
Zong-Xiang Ma, Peng Xu, X. Guan et al.· Journal of Instrumentation· 0 citations
Purpose: Alpha particles from $^{214}$Po, $^{212}$Po, and $^{210}$Po are increasingly used to calibrate large liquid scintillator detectors, but Geant4 simulations of their energy deposition require detailed validation. Methods: We simulate alpha particles in a 4 m cube of LAB-based liquid scintillator with Geant4 11.4...
LiquidO detectors confine scintillation light near its point of production by stochastic scattering in an opaque medium and collect it with a lattice of wavelength-shifting (WLS) fibers. The elementary signal of such a detector is the point-like sub-MeV energy deposition, yet the response to that signal at the center o...
L. Katz, J. Moffatt, G. Wendel et al.· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.