Oct 2026· Physics in Medicine and Biology· 0 citations· 58 references
PhysicsComputer ScienceMedicine
TL;DR
The proposed framework improved carotid PET segmentation and uptake quantification under simulated conditions and requires external validation with biological reference standards before clinical deployment.
Abstract
Abstract Objective. To develop an automated method for segmentation and uptake quantification of carotid atherosclerotic inflammation on 64Cu-CANF-comb PET while accounting for partial-volume and tissue-fraction effects. Approach. Synthetic carotid PET images with known fractional-volume ground truth were generated by combining MR-derived high-resolution activity maps with GATE Monte Carlo simulation incorporating major PET physical processes and matched to the Biograph mMR acquisition and reconstruction. A two-stage network first localized the carotid vessel wall from T1-weighted MR and then estimated voxel-wise inflammation fraction from masked PET. Both stages used a multiscale residual (MSR) convolutional backbone. Performance was compared with U-Net, Transformer U-Net, DUCK-Net, and iterative Yang partial-volume correction. Main results. In a two-alternative forced-choice study, five nuclear-medicine physicians identified real images with 54% accuracy (54/100; Wilson 95% CI 0.44-0.63; exact binomial p = 0.48). On 184 simulated test slices from five held-out patients, the proposed method achieved a weighted DSC of 0.79, compared with 0.73 for U-Net, 0.69 for Transformer U-Net, and 0.75 for DUCK-Net, with corresponding HD values of 1.85, 2.29, 2.32, and 2.23 voxels. Patient-cluster bootstrap comparisons favored the proposed method for DSC and HD against all three baselines (Holm-corrected p ≤ 0.031). Overall ENRMSE was 0.24 versus 0.59, 0.68, and 0.59 for the three DL baselines and 0.57 for iterative Yang. In seven patients, corrected SUV showed a positive association with MR-derived lipid-rich/necrotic core with hemorrhage. Significance. The proposed framework improved carotid PET segmentation and uptake quantification under simulated conditions. The patient analysis is preliminary and requires external validation with biological reference standards before clinical deployment.
The proposed hybrid DL-ML pipeline provides an accurate, interpretable, and clinically feasible solution for automated carotid atherosclerosis diagnosis and demonstrates that improved segmentation significantly enhances classification performance.
S. B. Baray, R. Sarmun, M. Islam et al.· Physical and Engineering Sci...· 0 citations
Objective interpretation of myocardial 99mTc-pyrophosphate (PYP) uptake is important in suspected cardiac amyloidosis. We developed a segmentation-informed multimodal framework that classifies myocardial PYP uptake from planar and single-photon emission computed tomography (SPECT) images. The retrospective, class-enric...
Jia-Shu Zhang, K. Imamura, T. Shibutani et al.· Electronics· 0 citations
The CFAPS system enables fully automated, robust, and interpretable segmentation and risk stratification of carotid plaques using multi-contrast HR-VWI, demonstrating strong generalizability and clinical utility.
Qun Gai, Yue Zhang, Jin-Xu Liu et al.· BMC Medicine· 0 citations
Objective. Deep learning-based segmentation of pulmonary vessels is challenged by vessel-nodule confusion and insufficient detection of small vessels. To address these issues, we propose a Nodule-aware High-abundance Pulmonary Vessel Segmentation (NHPVS) framework that enhances nodule differentiation and improves small...
Rui-Jie Zhao, Shao-Li Luo, Long-Fei Zhao et al.· Physics in Medicine and Biol...· 0 citations
Overall, MCP-Net provides a competitive and computationally efficient framework for automated multi-structure cardiac cine-MRI segmentation and external validation on the M&Ms benchmark without retraining or fine-tuning demonstrated the effectiveness and cross-dataset generalization capability of MCP-Net.
A. Kermi, Imane Cherifi, M. T. Khadir· SN Computer Science· 0 citations
Automated aortic segmentation in 4D flow MRI is essential for reproducible hemodynamic assessment but is limited by scarce dense annotations and high computational demands. We developed a fully automated 4D (3D+time) U-Net for segmenting the ascending aorta, arch, and proximal descending aorta, using a parameter-effici...
Hinrich Rahlfs, Julio Garcia, C. Manini et al.· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.