Jul 2026· Annals of Nuclear Medicine· 0 citations· 17 references
Medicine
TL;DR
The biodistribution of 18F-flortaucipir whole-body biodistribution for Japanese individuals was consistent with that of non-Japanese individuals, and Japanese readers showed high concordance with US readers on the interpretation of 18F-flortaucipir PET images to distinguish between AD and non-AD patterns.
Abstract
Objective
18F-flortaucipir (Tauvid™) is an 18F-labeled diagnostic positron emission tomography (PET) radiopharmaceutical, which was developed to detect tau pathology in the brain and to estimate the density and/or distribution of aggregated tau neurofibrillary tangles for patients being evaluated for Alzheimer's disease (AD). The objective of this article is to report findings from two studies. The primary objective of the first (dose and biodistribution) study was to investigate the consistency of 18F-flortaucipir PET biodistribution between Japanese and non-Japanese individuals. In the second (reader) study, the comparability of visual reads performed by Japanese and US expert readers who followed the same training program was evaluated.
Methods
This article reports findings from two separate studies and datasets. In the dose and biodistribution study, whole-body distribution of 18F-flortaucipir was assessed (N = 9). Standardized uptake value ratios, normalized to the entire cerebellum, were calculated, and whole-body effective dose was calculated using a 73.7 kg bodyweight model. In the reader study (Study A27; I7E-AV-A27), five Japanese physicians visually interpreted 60 PET scans randomly selected from a previous US reader study (Study FR01; NCT03901092). Scan positivity was determined based on increased activity of 18F-flortaucipir in posterolateral temporal, occipital, or parietal/precuneus regions with or without frontal activity. Each scan was visually interpreted by all Japanese readers, who determined whether scans were consistent with an AD or non-AD pattern. Concordance between Japanese and US readers who underwent the same training on the interpretation of 18F-flortaucipir PET images was then evaluated (reader study primary endpoint).
Results
The biodistribution of 18F-flortaucipir was consistent between Japanese and non-Japanese individuals. When interpreting 18F-flortaucipir PET images to distinguish between AD versus non-AD patterns, Japanese and US readers who underwent the same training showed 100% agreement on the majority reads, with a Cohen's Kappa value of 1.
Conclusions
18F-flortaucipir whole-body biodistribution for Japanese individuals was consistent with that of non-Japanese individuals. After completing the same training, Japanese readers showed high concordance with US readers on the interpretation of 18F-flortaucipir PET images to distinguish between AD and non-AD patterns. Data and scans were from previous studies registered with ClinicalTrials.gov (registration numbers: NCT04474405; NCT03901092).
High-resolution dhPET revealed significantly higher SUVRs in Aβ⁺ compared with Aβ⁻ subjects in supratentorial structures, including cerebral white matter, and in cerebellar gray matter.
Yasuyuki Kojita, Kazunari Ishii, Takahiro Yamada et al.· Annals of Nuclear Medicine· 0 citations
It is concluded that [18F]-Florzolotau PET provides a robust in vivo measure of AD tau burden, motivating further evaluation for diagnostic and prognostic applications.
Simone Lista, P. Minoretti, Enzo Emanuele et al.· Journal of Alzheimer's Disea...· 0 citations
Generalized additive models examined clinical progression on the basis of visual and CenTauRz-based assessments of tau PET positivity and highlighted the need for new quantification approaches to better capture the complex patterns of tau deposition, important for early AD detection and monitoring.
Stamatia Karagianni, Alexis Moscoso, Sheelakumari Raghavan et al.· Journal of Nuclear Medicine· 0 citations
The combined PET/MRI model demonstrated improved discriminative performance for assessing active and inactive ; however, further validation in larger independent cohorts is required.
Xueqian Yang, Lin-Yang Gan, Xi-Min Shi et al.· European Journal of Nuclear...· 0 citations
A narrative review of the principal Aβ positron emission tomography radioligands and their methodological framework, including visual reads, the standardized uptake value ratio, and the Centiloid scale, which harmonized quantitative output across tracers, scanners, and protocols and may enable cross-site comparison in...
Simone Lista, L. Filippi, Enzo Emanuele et al.· Molecular Diagnosis & Therap...· 0 citations
Hypometabolism is a sensitive and early marker of AD-related neurodegeneration, preceding MRI-detectable GM atrophy and more closely reflecting underlying tau pathology across disease stages.
Orfeas Vourkas, Linda Zhang, Andrés Jiménez-Pérez et al.· European Journal of Nuclear...· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.