Skip to content
Open access

PHB/ErGO electrochemical immunosensor for H5N1 serology: Insights into selectivity and inflammation-mediated matrix effects.

Oct 2026 · Biosensors & bioelectronics · Vol 316, pp. 119339 · 0 citations · 26 references
Medicine

Abstract

Reliable electrochemical immunosensing in biological samples requires not only selective molecular recognition but also preservation of analytical performance in complex matrices. Here, a label-free electrochemical immunosensor based on electrochemically reduced graphene oxide (ErGO) and polyhydroxybutyrate (PHB) nanoparticles was developed for the detection of anti-H5N1 antibodies in chicken serum. PHB nanoparticles were pre-functionalized with H5N1 hemagglutinin and deposited onto disposable ErGO-modified screen-printed electrodes, providing a simplified strategy for biointerface assembly. Structural, morphological, and electrochemical characterization confirmed the formation of the sensing interface and its response to antibody binding. The immunosensor exhibited a linear response from 1 pg mL-1 to 10 ng mL-1, with a detection limit of 1 pg mL-1, and showed selective recognition of anti-H5N1 antibodies in the presence of unrelated viral antibodies and proteins. Systematic comparison of PBS, healthy serum, and inflammatory serum revealed a progressive reduction in analytical sensitivity, with calibration slopes of 5.53, 3.03, and 1.69, respectively, accompanied by increased baseline suppression. Nevertheless, concentration-dependent responses and target discrimination were maintained in serum matrices. These findings support the use of the ErGO/PHB interface for anti-H5N1 detection and quantify the loss of analytical sensitivity observed in the serum conditions investigated.

Read PDF

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.