Outcomes of Fourth-Generation HIV Screening and Confirmatory Testing at a Tertiary Care Center: Evaluation of 286,425 Patient Samples

Sep 2026 · Klimik Dergisi/Klimik Journal · 0 citations

Abstract

Objective: Fourth-generation human immunodeficiency virus (HIV) antigen/antibody assays reduce the diagnostic window; however, reactive results necessitate further evaluation. The objective of this study was to characterize the distribution of samples across the stages of HIV screening and confirmatory testing in a high-volume tertiary-care laboratory and to identify confirmed HIV infections. Methods: This retrospective descriptive study analyzed 286,425 unique serum samples from patients aged 18 years or older, collected between May 2024 and January 2026. Initial screening was conducted using fourth-generation HIV antigen/antibody assays on the Atellica IM or ADVIA Centaur systems. Samples demonstrating repeated reactivity underwent further testing with the VIDAS HIV Duo Quick assay. VIDAS-reactive samples were referred to a reference laboratory for supplemental serological testing. HIV-1 RNA testing was performed using the NeuMoDx platform through June 2025 and the ELITe BeGenius platform from July 2025 onward. Data analyses were descriptive. Results: Among the 286,425 patient samples, 4480 tested repeated reactivity on the initial screening platforms (1.56%; 95% confidence interval [CI], 1.52%–1.61%). Of these, 1378 samples (30.76%) remained reactive on VIDAS, while 3102 (69.24%) were VIDAS-nonreactive and did not undergo HIV-1 RNA testing or reference laboratory confirmation. HIV infection was confirmed in 188 of the 1378 referred samples (13.64%; 95% CI, 11.87%–15.57%), including 100 newly diagnosed cases and 88 with a prior HIV diagnosis. Final results for the remaining 1190 samples were unavailable. In total, 5050 HIV-1 RNA tests were performed during the study period. Conclusion: Discordant reactivity was identified between the initial screening platforms and VIDAS. This discordance may be attributable to low pretest probability, variations in antigen/antibody capture designs and analytical thresholds, or nonspecific reactivity. Due to the absence of verification data for VIDAS-nonreactive samples and VIDAS-reactive samples without final results, sensitivity, specificity, and predictive values could not be determined.

Read PDF

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.