Mechanical Performance of Beam-Column Joints in Glued Laminated Timber Structures: A Design Evaluation and Idealized Envelope Approach
Abstract
Beam–column connections play a critical role in load transfer and lateral stability in Glued Laminated Timber (GLT) frame buildings. Assessing their design performance, however, requires both a check against design standards and a measure of stiffness and connection ductility, which normally depends on continuous load–displacement records. Such records are often unavailable. This study proposes an assessment framework for four beam–column connections, two in shear and two in tension, taken from a Vietnamese-Japanese prototype GLT building made of Japanese cedar. Peak loads from full-scale tests were processed using the small-sample method of EN 14358 to obtain characteristic values, which were then checked against Eurocode 5. To recover stiffness and ductility from peak data alone, a tri-linear idealized envelope was constructed and tested for sensitivity, and the three parameters were combined into a single performance index to rank the connections. The framework demonstrates that a transparent, standards-based assessment is possible even when only peak-state data are available, while supporting the safe and material-efficient use of prefabricated GLT connection systems for sustainable and low-carbon building applications.