Skip to content
Open access

Factors Affecting the Accuracy of Surgical Guide

Jul 2026 · Dentistry 3000 · Vol 14 · 0 citations · 4 references

TL;DR

To compare the accuracy of surgical guides manufactured with two different 3D printers, two resins, two different occlusal designs, and interactions of these factors were used,criptive statistics and a multivariate analysis of variance (MANOVA) were conducted.

Abstract

To compare the accuracy of surgical guides manufactured with two different 3D printers, two resins, two different occlusal designs (OS: original shape, and GS: groove sealing), and interactions of these factors were used. Forty surgical guides were printed on a digital light processing (DLP) printer and a Liquid Crystal Display (LCD) printer, with two resin types (SG guide and V-guide) and two occlusal designs. The region where the implant was planned was digitally removed from the cast, allowing passive positioning of the implant through the guide. A scan body was inserted in the implant, and the cast was scanned with an intraoral scanner. The planned implant compared with the actual implant position. Six measurements representing the accuracy of implant placement: (depth, angular, global apical, horizontal apical, global coronal, and horizontal coronal) deviations. Descriptive statistics and a multivariate analysis of variance (MANOVA) were conducted. Printer type had a statistically significant multivariate effect (Wilks’ Lambda = 0.015, p< 0.001, Partial η² = 0.985). The resin type had no multivariate effect on the combined dependent variables, as indicated by Wilks’ Λ = 0.727, p = 0.161. Occlusal shape showed a significant multivariate effect (Wilks’ Lambda = 0.015, p<0.001). The univariate tests revealed that printer type and the shape of the occlusal surface had a statistically significant effect on all six deviation parameters (p < 0.001 for all); however, resin type had a significant effect only on horizontal coronal deviation (p = 0.018). The multivariate analysis using Wilks’ Lambda revealed a significant interaction effect between printer and resin (Wilks’ Λ = 0.593, F (6,27) = 3.094, p = 0.019, Partial η² = 0.407), A significant interaction was also observed between printer and occlusal design (Wilks’ Λ = 0.445, F (6,27) = 5.606, p = 0.001, Partial η² = 0.555) and between printer, resin, and occlusal surface (Wilks’ Λ = 0.414, F (6,27) = 6.380, p < 0.001, Partial η² = 0.586). The DLP printer group and groove sealing group were more accurate than the LCD printer, and occlusal surface group. The accuracy of both SG and V-guide resins was the same.

Read PDF

Similar papers

Open access Sep 2026

Evaluation of the Accuracy of Dental Implant Placement on Different Cast Models

Introduction: To compare the accuracy of implant placement on mandibular models fabricated from different materials using a single digitally designed surgical guide, and to identify which model provided the highest precision and cost-effectiveness for research and training applications. Materials and Methods: Nine ide...

Raniah Isam Muwafaq al Khashali, Dr. Bayad Jaza Mahmood · 0 citations
Open access Oct 2026

Influence of 3D Printing, Implant Macro-Design and Alveolar Ridge Morphology on Accuracy and Primary Stability in Static Computer-Assisted Implant Surgery: An In Vitro Study.

OBJECTIVES To assess the positional accuracy of static computer-assisted implant surgery (sCAIS) using guides printed by digital light processing (DLP) or material extrusion (ME), and to compare insertion torque (IT) and implant stability quotient (ISQ) of two tissue-level implants (Straumann TLC, TLX) in healed premol...

Malte Bagratuni, S. Abou-Ayash, Justus Pook et al. · 0 citations
Open access Oct 2026

Accuracy of implant according to support type of dental implant surgical guides: A retrospective study

Purpose: This study evaluated the influence of surgical guide support type on implant placement accuracy by comparing planned and actual implant positions.Materials and Methods: Thirty-two patients who underwent guided implant surgery between January 2024 and April 2026 were included. 136 implants were analyzed: 60 in...

K. Im, Gi-Won Sung, Ho-Young Cha et al. · 0 citations
Sep 2026

Effect of Material Type and Printing Orientation on the Marginal and Internal Fit of Additively Manufactured Definitive Resin Crowns: A Micro-Computed Tomography Study.

OBJECTIVE To investigate the effects of material type and printing orientation on the marginal, axial, and occlusal fit of additively manufactured definitive resin crowns using micro-computed tomography (micro-CT). METHODS Seventy definitive resin crowns were allocated to 10 groups according to material type (Saremco...

Destina Suay Sarı, Hatice Sevmez · 0 citations
Open access Oct 2026

Accuracy of augmented reality-assisted versus template-guided implant surgery: an in-vitro comparative study.

This in-vitro comparative study aimed to examine the accuracy of augmented reality-assisted implant placement compared to the conventional drilling templates. Twenty maxillary bone models were used to perform 80 implant placements using two different methods. Every bone model received four implants: two were placed usi...

F. A. Bosshard, T. Di-Giovanni, L. Schaufelberger et al. · 0 citations
Open access Oct 2026

Comparative Evaluation of the 3-Dimensional Implant Impression Accuracy between Conventional and Digital Impression Using Two Different Intraoral Scanners: An In Vivo Study

Background: Accurate three-dimensional (3D) recording of implant positions is fundamental to achieving passive fit and long-term success of implant-supported prostheses. The growing adoption of digital intraoral scanners (IOS) necessitates rigorous clinical evaluation of their accuracy relative to established conventio...

Rahul Ranjan, Anju Aggarwal, Punit R. S. Khurana et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.