These findings support metasurface-enhanced THz sensing with full-spectrum deep learning as a rapid ex vivo adjunct for molecularly relevant assessment of diffuse glioma specimens.
Abstract
Molecularly informed maximal safe resection of diffuse glioma requires rapid assessment of surgical specimens, but conventional molecular assays are not suited to repeated ex vivo testing. We developed a deep learning-assisted terahertz (THz) metasurface workflow in which a K/I-patterned aluminum metasurface both serves as the cryosection-receiving substrate and converts tissue-induced dielectric perturbations into multi-resonance THz responses. After preliminary thickness optimization, 50 μm sections were prepared directly on the active sensing area. The study included 53 patients, 59 tissue specimens, and 590 nested block-level spectra. A SEResNet1D model analyzed the complete 0.50-1.12 THz transmittance curve using a patient/specimen-grouped hold-out design. Distinct from prior conventional THz molecular studies and metasurface studies focused mainly on tumor-normal contrast, cultured cells, or animal imaging, the workflow integrates direct on-metasurface cryosectioning, resonant multi-mode THz transduction, full-spectrum deep learning, and leakage-aware grouped validation for five-class molecularly relevant assessment of human diffuse glioma frozen sections. Across five independently initialized runs, SEResNet1D achieved a mean five-class accuracy of 97.48 ± 0.87%. One THz spectrum required approximately 8 s, and a ready-to-scan tissue-sensor unit could be prepared in approximately 3 min. These findings support metasurface-enhanced THz sensing with full-spectrum deep learning as a rapid ex vivo adjunct for molecularly relevant assessment of diffuse glioma specimens.
Early and accurate cancer diagnosis remains a critical challenge in clinical oncology due to the limitations of traditional, destructive labeling methods. To address this gap, this study proposes a novel, label-free quad-band terahertz (THz) metamaterial biosensor designed for high-precision fingerprint identification...
Aykut Coşkun, A. Özmen· Italian National Conference...· 0 citations
Findings support proof-of-concept signal enhancement in a subcutaneous xenograft model but do not establish a clinical tumor-to-normal-lung contrast ratio.
Jin Zhu, Yang Li, Xiao-Xue Zhang et al.· Frontiers in Bioengineering...· 0 citations
Terahertz (THz) biophotonics offers unique capabilities for label-free and non-destructive analysis of biological samples. However, its widespread application has been limited by the diffraction limit of THz waves and their strong absorption by water. To address these challenges, we developed a point THz source generat...
K. Serita· Optical Engineering + Applic...· 0 citations
Terahertz (THz) metasurface absorbers have attracted significant interest for wideband energy harvesting, electromagnetic stealth, and sensing applications. However, the design of ultra-wideband THz absorbers still relies heavily on empirical optimization and time-consuming full-wave simulations, particularly when high...
Pin Wen, Jin-Yu Liu, Kun Zhan et al.· IEEE Journal of Selected Top...· 0 citations
The clinical success of immunotherapies is hindered by the absence of robust methodologies for the early and accurate assessment of antitumor immune responses. Integrating engineered biomaterials with artificial intelligence (AI)-driven molecular imaging technology offers a powerful approach for predicting immune effic...
Kai-Wei Lv, Bin Li, Bing Xiao et al.· Advanced Healthcare Material...· 0 citations
Spectral photon-counting computed tomography (SPCCT) enables material-resolved imaging through K-edge discrimination, yet its application to multiplexed molecular mapping of human surgical specimens remains underexplored. Here, we report a clinically relevant multiplex K-edge imaging strategy and demonstrate its utilit...