Skip to content

PULL-OUT BEHAVIOR OF CROSS-LAMINATED TIMBER CONNECTIONS USING STEEL RODS AND LAG SCREW BOLTS

Sep 2026 · Proceedings of International Structural Engineering and Construction · Vol 13 · 0 citations · 3 references

Abstract

This paper investigates the use of Cross-Laminated Timber (CLT) as support members for seismic panel damper systems in steel-framed structures to promote the utilization of forest resources. Steel beams and CLT members are connected using lag screw bolts (LSBs) and hexagonal bolts to transfer tensile and shear forces. As the base ends of the CLT support members are subjected to tensile forces during seismic loading, it is necessary to evaluate the pull-out strength of the LSBs. Since the pull-out failure of LSBs exhibits brittle behavior, a connection method using steel rods as intermediaries was investigated. A reduced section in the shank of the steel rod promotes plastic deformation, thereby mitigating the brittle behavior of the LSBs. This study conducted pull-out tests to evaluate the tensile performance of the connection. The results indicated that specimens with a reduced section reached approximately 91% of the maximum strength of those without a reduced section, due to the decrease in the shank's cross-sectional area. In contrast, the deformation at the point of rod fracture increased by an average of 4.75 times, as the reduced section underwent significant plastic deformation. It was found that the plastic deformation of the reduced section prevents brittle pull-out failure of the LSBs, resulting in behavior characterized by enhanced deformation capacity.

View source

Similar papers

Open access 2026

Shear performance analysis of CLT–steel hybrid joints: Effects of fastener geometry and FRP reinforcement

Cross-laminated timber (CLT) slabs and steel beams can be combined to form hybrid floor systems for long spans and heavy loads. The performance of these systems depends greatly on the shear connections between the CLT slabs and steel beams. In this study, push-out tests were conducted on CLT–steel joints connected with...

Seung-Youp Baek, Soon-Il Hong, Yo-jin Song · 0 citations
Open access Oct 2026

Fatigue behavior of threaded rods bonded into glued-laminated timber for application in bridge construction

Due to the difficult climatic conditions and the fatigue stresses caused by traffic loads, timber is used comparatively little in bridge construction. Connections with bonded in rods (BiR) are of particular interest for structures with fatigue loads, as they allow a very uniform force transfer. So far, most of the fati...

R. Steiger, Bruno Zumbrunn-Maurer, L. Kramer et al. · 0 citations
Open access Sep 2026

Shear Behaviour of Polyurethane Screw-Glued and Serrated Steel Plate Flange-to-Web Joints in Ribbed CLT Panels

The present study investigates the shear behaviour of screw-glued and mechanical flange-to-web connections intended for cross-laminated timber (CLT) ribbed panels, with the aim of improving composite behaviour and enhancing the structural performance of long-span timber floor and roof systems. Fifteen CLT-glue laminate...

Elza Briuka, Ernests Kiops, D. Serdjuks et al. · 0 citations

in steel-to-timber

Yue Wang, Caroline D. Aquino, R. Crocetti et al. · 0 citations
Open access Sep 2026

LOAD-TRANSFER MECHANISMS IN TIMBER CONNECTIONS USING DENSIFIED WOOD AND STEEL DOWELS: AN EXPERIMENTAL AND NUMERICAL STUDY

This study presents an experimental and numerical investigation of the mechanical behaviour of L-shaped timber connections assembled using densified wood dowels and steel dowels under ambient mechanical loading conditions. Mechanical tests were con-ducted on a multilayer timber beam–column connection to determine the l...

Trong Tuan Tran, N. Nguyễn · 0 citations
Open access Oct 2026

Bond Behavior of CFRP/Steel Double Strap Joints: An Experimental Study

The performance of steel elements retrofitted with carbon fiber-reinforced polymer (CFRP) relies on the bond behavior of the interface between CFRP and steel substrate, as the adhesive is typically the weakest link of the retrofitting system. Therefore, understanding the bond behavior between CFRP and steel substrate i...

Mohamadreza Delzendeh, O. Chaallal · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.