Skip to content
Open access

Superior precision of clinical predictions after CD3-relativisation to align flow cytometry data

Aug 2026 · EBioMedicine · Vol 131, pp. 106427 · 0 citations · 66 references
Medicine

TL;DR

A benchmark flow cytometry dataset assembled using 6 cytometers at 4 independent laboratories in Spain and Germany establishes a robust standard for evaluating computational methods in clinical cytometry, especially their stability over time and generalisability between instruments, laboratories and clinically heterogeneous populations.

Abstract

Summary Background Flow cytometry captures subtle changes in immune cell distributions caused by disease, but its full potential in medical decision-making is presently limited by technical variability across instruments, sites and time. To accelerate development of generalisable diagnostic, prognostic or predictive clinical tests, we assembled a benchmark flow cytometry dataset over 20 months using 6 cytometers at 4 independent laboratories in Spain and Germany. Cohorts were amalgamated using a new alignment strategy, CD3-relativisation. Methods Four hundred and eighty-two clinical flow cytometry samples from 381 healthy donors and a further 100 samples from post-surgical patients admitted to intensive care were stained with a 10-colour T cell marker panel. To align data from different cohorts, we introduced CD3-relativisation, a method for normalising fluorescence intensities per-channel against CD3 signals. The quality of data alignment was evaluated using optimal transport distances (OTD), clustering consistency and predictive performance. Findings Our fully annotated data resource (Zenodo 17094078) revealed systematic biases in flow cytometry measurements across time, locations and cytometers. CD3-relativisation minimised these biases without sacrificing biological information. Cell clustering performance and sample-to-sample variability improved after relativisation. Consequently, we were able to predict CMV-IgG serostatus, age and sex with superior precision without relying upon external calibrators, measurement of paired samples, batch definitions or data sharing. Models established in healthy control populations were transferable to a cohort of critically unwell, post-surgical patients. Interpretation Our CD3-relativised benchmark dataset establishes a robust standard for evaluating computational methods in clinical cytometry, especially their stability over time and generalisability between instruments, laboratories and clinically heterogeneous populations. Funding This work was supported by the BMS-Foundation (FA-19-009), BZKF (BF/04/R/Hutch), EU-H2020 (Immutol_101080562, exTra_101119855, PAVE_861190), BMBF (01KD2206I) and DFG (403161218).

Read PDF

Similar papers

Open access Aug 2026

Comprehensive leucocyte subsets assay in healthy adults using multiparametric flowcytometry

Background and objectives Comprehensive immune-cell subset characterisation in healthy adults is the prerequisite for enabling accurate diagnosis of primary immunodeficiencies and informed therapeutic decision-making in targeted immunotherapies. Herein, we aim to establish biological reference intervals (BRIs) for leuk...

N. Das, Rahul Katharia, S. Pabbi et al. · 0 citations
Open access Aug 2026

Diagnostic regulatory pathways are an underrecognized bottleneck in precision oncology clinical trials: Real-world evidence across Europe.

Biomarker strategies and diagnostic testing approaches should be thoughtfully constructed and considered pragmatically, as inefficient implementation may directly affect trial interpretability, efficacy assessment and regulatory success, substantially compromising trial delivery in Europe.

Sarah Hersey, Haydar Çelik, Steven T. Rosen et al. · 0 citations
Aug 2026

Standardized Multicolor Flow Cytometry Protocol for Measurable Residual Disease Assessment in Acute Leukemia.

The protocol incorporates strict specimen acceptance criteria, with integrated hemodilution assessment, and uses a bulk red blood cell lysis method for bone marrow and peripheral blood specimens, and provides a practical framework for standardized MRD monitoring.

Lin-Lin Li · 0 citations
Sep 2026

FlowLOT: Linearized Optimal Transport for Flow Cytometry Analysis.

FlowLOT is introduced, an optimal-transport-based framework that models the single-cell measurement data of a pa- tient sample as an empirical cellular distribution and maps it directly into a fixed-length feature vector and unifies high-dimensional classification, interpretable visualization, and continuous quantitati...

Naqib Sad Pathan, Mohammad Shifat-E.-Rabbi, Kristofor E. Pas et al. · 0 citations
#machine learning Preprint Sep 2026

Interpretable Multi-Instance Learning Enables Early Prediction of Key Molecular Alterations from Routine Flow Cytometry in Acute Myeloid Leukemia

Results show that an interpretable model applied to data already collected in routine care can predict AML molecular status within hours, offering a practical route to earlier, biology-informed treatment decisions.

Jonathan Legrand, Aguirre Mimoun, B. D. de Senneville et al. · 0 citations
Open access Sep 2026

Radiomics in Precision Medicine: Barriers to Clinical Translation - A Critical Analysis

Radiomics translation requires a paradigm shift from discovery-centric to validation-centric practice, underpinned by mandatory harmonization protocols, prospective multi-site designs, and regulatory co-development.

Ashish Yadav, Mitali Monalisha, Priyanka Yadav et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.