Skip to content

Clinical Evaluation of Metal-Ceramic and Zirconia Molar Crowns: 15-Year Results from a Practice-Based Cohort Study.

Oct 2026 · International Journal of Prosthodontics · Vol 0 0, pp. 1-23 · 0 citations
Medicine

TL;DR

ZC demonstrated 15-year ECSv, ECSc, and VCSc values comparable to those of MCCs, and crowns on terminal abutment teeth carry a significantly increased risk of absolute failure and clinical intervention.

Abstract

Purpose

This practice-based study evaluated the clinical performance of conventionally luted fully veneered metal-ceramic (MCC) and zirconia molar crowns (ZC). MATERIAL AND

Methods

Between July 2008 and July 2009, 53 patients were restored with MCCs or ZCs. Forty-four patients (26 female) with 91 restorations (MCC: 41 / ZC: 50, mean observational period: 158 ± 28 months) attended regular clinical follow-ups and were included. Estimated cumulative survival (ECSv), success (ECSc), and veneering ceramic success (VCSc) were calculated (Kaplan-Meier) and analyzed by the crown fabrication technique, abutment vitality, and the position of the restoration (Cox regression model) (p < 0.05).

Results

Nineteen absolute failures (MCC: 9, ZC: 10) were recorded (15-year ECSv: MCC: 82%, ZC: 78%). A total of 41 interventions (MCC: 18, ZC: 23) were necessary to maintain the restorations (15-year ECSc: MCC = 68% / ZC = 58%). Non-significant differences in ECSv (p=0.707), ECSc (p=0.375), and VCSc-rates (p=0.596) were determined for the two fabrication techniques. Restorations placed on terminal abutment teeth demonstrated a 3.6-fold increased risk (p=0.003) for complete failure and a 2.3-fold increased risk (p=0.007) for a clinical intervention compared to restorations with two neighboring teeth.

Conclusion

In the present study, ZC demonstrated 15-year ECSv, ECSc, and VCSc values comparable to those of MCCs. Irrespective of the fabrication technique, crowns on terminal abutment teeth carry a significantly increased risk of absolute failure and clinical intervention.

View source

Similar papers

Oct 2026

Evaluation of full-veneer crowns fabricated with 3D printing resin material for definitive prostheses: A 1-year randomized controlled prospective study.

The definitive 3D-printed resin crowns showed acceptable marginal adaptation but greater measured occlusal wear and a numerically higher fracture incidence than monolithic zirconia crowns over 1 year may raise concerns regarding mechanical durability as definitive posterior single crowns.

Heedo Shin, K. Oh, Jee-Hwan Kim · 0 citations
Oct 2026

Monolithic Zirconia Versus Porcelain-Fused-To-Metal Implant- Supported Fixed Dental Prostheses in the Posterior Region: 1- Year Results of a Randomized Controlled Clinical Trial.

PURPOSE To compare the early clinical, biological, and technical outcomes of three-unit implant-supported fixed dental prostheses (iFDPs) fabricated from monolithic zirconia (MonoZR) versus porcelain-fused-to-metal (PFM) in the posterior region. METHODS In this prospective, superiority randomized controlled clinical...

Aspasia Pachiou, K. Herren, Ronald E. Jung et al. · 0 citations
Review Open access Sep 2026

Three-Year Clinical Outcomes of Lithium Disilicate and Lithium-Silicate-Modified Zirconia Veneers and Partial-Coverage Restorations: A Retrospective Comparative Study

Background: Clinical evidence regarding lithium-silicate-modified zirconia veneers and partial-coverage restorations remains limited. This retrospective study compared the observed three-year outcomes of two complete adhesive restorative protocols rather than the isolated effects of ceramic materials. Materials and Met...

A. Măroiu, A. Faur, Andra Ardelean et al. · 0 citations
Open access Oct 2026

Clinical performance of ultratranslucent monolithic zirconia posterior crowns compared with lithium disilicate crowns: A pilot, randomized, double-blind, controlled clinical trial.

PURPOSE To evaluate, through a pilot, randomized, double-blind, controlled clinical trial, the clinical performance of ultratranslucent monolithic zirconia (UTZr) compared to lithium disilicate (LD) posterior crowns after 24 months of follow-up. MATERIALS AND METHODS Twenty-four crowns were fabricated and placed in 1...

L. M. Miranda, I. G. D. de Carvalho, L. D. de Araújo et al. · 1 citation
Open access Oct 2026

Clinical and Microbiological Outcomes of Implant-Supported Hybrid Abutment Crowns in the Posterior Region as a Function of Restorative Material: Exploratory Results of a 36-Month Randomized Clinical Trial

Background: Hybrid abutment crowns combine a prefabricated titanium base with a custom, CAD/CAM-fabricated ceramic superstructure. Despite their increasing clinical use, only limited long-term in vivo data are available on how the restoration material influences clinical and microbiological outcomes. Objective: We inve...

S. Schnutenhaus, Marla Weinmann, C. Olms et al. · 0 citations
Open access Oct 2026

Comparative assessment of bioactive core materials and conventional composite cores in supporting full-coverage crowns on endodontically treated teeth

Endodontically treated teeth require reliable core restorations, but the biological and mechanical performance of bioactive and conventional materials remains unclear. This study compared 120 endodontically treated teeth restored with Biodentine (n = 60) or ParaCore (n = 60), evaluating biological, mechanical and 12-mo...

A. Pahwa · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.