Skip to content
Open access

Electrochemical Detection of Hg(II) Using EASA-Derived Glutathione-Modified Mesoporous Silica Films

Oct 2026 · Chemistry · 0 citations · 33 references

Abstract

Mercury contamination threatens aquatic ecosystems and human health because of its toxicity, persistence, and potential for bioaccumulation. This study investigated an electrochemically assisted self-assembly (EASA)-derived glutathione-modified thiol-functionalized mesoporous silica film on a fluorine-doped tin oxide (FTO) electrode as a proof-of-concept interface for Hg(II) detection. Films containing 5–15 mol% (3-mercaptopropyl)trimethoxysilane (MPTMS) were evaluated using charged redox probes, and the 10 mol% composition produced the highest electrochemical response. FTIR analysis supported silica-network formation and the retention of glutathione-associated functional groups. Under the selected conditions of pH 5.0, a deposition potential of −0.70 V, and a deposition time of 5 min, the MSF-GSH/FTO electrode exhibited a linear response from 5 to 60 µM Hg(II), with an estimated calibration-based detection limit of 4.27 µM. Resolved oxidation peaks were observed for Hg, Pb, and Cd in a mixed-metal solution. The interface combines direct EASA film formation, thiol incorporation, and post-deposition glutathione modification; however, further sensitivity improvement, replication, stability testing, and real-sample validation are required.

Read PDF

Similar papers

Open access Oct 2026

Electrochemical Detection of Perfluorooctanoic Acid by a Zn–Terpyridine and Nafion‐Modified Glassy Carbon Electrode

Perfluorooctanoic acid (PFOA), a persistent organic pollutant, poses significant environmental and health risks due to its widespread occurrence in water sources and resistance to degradation. This study investigates zinc(II) terpyridine (Zn–tpy) complexes as molecular receptors for PFOA, demonstrating capture via carb...

A. Buzid, Kim J. Keohane, Sarah Cramp et al. · 0 citations
Open access Oct 2026

Hierarchical Ni-rGO nanocomposite derived from e-waste graphite for trace-level electrochemical sensing of metronidazole

Metronidazole (MTZ) accumulation in aquatic systems presents severe environmental and public health risks, requiring sensitive trace-level monitoring techniques. Here, we report the development of an electrochemical sensor based on a reduced graphene oxide (rGO) nanocomposite decorated with nickel-containing nanophases...

Abdullah Ibn Masud Mubin, M. Kabir, M. Ehsan et al. · 0 citations
Open access Oct 2026

Biochar copper nanocomposite modified sensor for the green electroanalytical sensing of paraquat

Paraquat (PQ) is a widely used herbicide categorized as an environmental contaminant due to its high toxicity and risk to aquatic ecosystems and human health. In this study, we developed a Screen-printed Disposable Polyethylene Terephthalate (SD-PET) sensor using a green sodium alginate/graphite conductive ink. To maxi...

E. Y. Ito, F. C. Barreto, M. Silva et al. · 0 citations
Oct 2026

Sensitive determination of arsenic in water using fluorescent CdS nanostructures.

This study presents a simple and sensitive fluorescence-based sensing platform for arsenic (As) detection in water using cadmium sulfide (CdS) nanostructures. Three morphologically distinct CdS nanostructures (nanorods, nanoparticles, and nanocubes) were synthesized via thermal decomposition of cadmium(II) bis(dibutylc...

I. Gul, Samra Gillani, Aqsa Khaliq et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.