Skip to content
#software testing Open access

AI-assisted versus point-based registration for digital planning in CBCT images with metallic artifacts

Oct 2026 · BMC Oral Health · Vol 26 · 0 citations · 18 references
Medicine

TL;DR

AI-assisted registration achieved significantly lower registration discrepancies than conventional point-based registration while maintaining comparable registration duration in CBCTs with metallic artifacts on CBCT images, suggesting that AI-assisted registration may improve the accuracy and consistency of multimodal image registration within the digital implant planning workflow, particularly in clinically challenging cases.

Abstract

Accurate registration between cone-beam computed tomography (CBCT) images and intraoral scans is fundamental to digital implant planning because registration errors may propagate throughout the digital workflow and affect the accuracy of computer-guided implant surgery. Conventional point-based registration relies on manually selected anatomical landmarks and may be compromised by metallic artifacts that obscure dental structures. Artificial intelligence (AI)-assisted registration has recently emerged as a promising alternative; however, evidence comparing its performance with conventional point-based registration under clinically challenging conditions remains limited. This study aimed to compare the registration accuracy (primary outcome) and registration duration (secondary outcome) of AI-assisted and conventional point-based registration in patients presenting with metallic artifacts on CBCT images. This study included 45 eligible patients with corresponding full-arch CBCT datasets and intraoral scans. Registration accuracy was evaluated at the arch level by measuring the mean discrepancy at three predefined anatomical landmarks using Geomagic Control X software. Registration duration was recorded for each workflow. Arches were classified according to artifact burden into mild (> 0–33%), moderate (> 33–66%), and severe (> 66%) categories. Because the data were non-normally distributed, paired comparisons were performed using the Wilcoxon signed-rank test. Generalized estimating equations (GEE) were used as a sensitivity analysis to account for clustering of maxillary and mandibular arches within the same patient. Intra-observer reliability was assessed using the intraclass correlation coefficient (ICC). A total of 78 paired arch observations were available for registration accuracy analysis. AI-assisted registration demonstrated significantly lower registration discrepancies than conventional point-based registration (median 0.190 mm [IQR 0.121–0.275] vs. 0.268 mm [IQR 0.200–0.418]; p < 0.001). Registration discrepancy increased with increasing artifact burden for both techniques, although AI-assisted registration consistently demonstrated lower discrepancies across all artifact severity groups. Registration duration was comparable between the two workflows. The GEE sensitivity analysis confirmed the primary findings after accounting for within-patient clustering. Intra-observer reliability was excellent (ICC = 0.985; 95% CI: 0.968–0.993). AI-assisted registration achieved significantly lower registration discrepancies than conventional point-based registration while maintaining comparable registration duration in CBCTs with metallic artifacts on CBCT images. These findings suggest that AI-assisted registration may improve the accuracy and consistency of multimodal image registration within the digital implant planning workflow, particularly in clinically challenging cases. Further prospective multicenter studies involving multiple implant-planning software platforms and broader clinical scenarios are required to confirm these findings.

Read PDF

Similar papers

Open access Oct 2026

Evaluation of registration accuracy using short‐arc cone‐beam computed tomography for image‐guided radiotherapy in breast cancer

Abstract Background Image‐guided radiotherapy (IGRT) using cone‐beam computed tomography (CBCT) enables highly accurate imaging registration; however, increased radiation exposure remains a concern. Recently, short‐arc CBCT (SA‐CBCT), which reduces projection data and reconstructs images, has become available. Although...

Shuhei Wada, M. Tominaga, M. Sasaki et al. · 0 citations
Review Open access Sep 2026

Automated quality assurance of rigid brain CT/MR image registration using a 3D convolutional neural network

Abstract Background Accurate CT/MR registration is important in stereotactic brain radiotherapy, where small spatial errors may affect target localization and treatment planning. In many clinical settings, registration quality is still assessed primarily through manual visual inspection. However, time and workflow cons...

Zeinab A. Chahrour, Noura Obeid, A. El-Zaart et al. · 0 citations

PLANNING TO THE CLINICAL-LABORATORY

Patrícia José Augusto Rodrigues, P. Novelli, L. B. Hanna et al. · 0 citations
Review Oct 2026

A Deep Learning-Based Method for Automatic Registration of Craniofacial CBCT and Multi-planar Temporomandibular Joint MRI.

OBJECTIVES To develop a fully automated multi-stage registration framework for temporomandibular joint (TMJ) imaging that enables spatial alignment between large-field-of-view cone-beam computed tomography (CBCT) and multi-planar small-field-of-view magnetic resonance imaging (MRI). METHODS The framework combined lan...

Yi-Chen Pan, Lu-Qi Yang, Zhi-Ming Cui et al. · 0 citations
Open access Oct 2026

Diagnostic performance of clinical photon-counting CT in the assessment of peri-implantitis – an ex vivo diagnostic accuracy study

To evaluate the diagnostic performance of photon-counting computed tomography (PCCT) for the assessment of peri-implant bone defects and to compare it with cone-beam computed tomography (CBCT) at comparable radiation doses. Circular peri-implant defects were artificially created around 27 titanium implants placed in ni...

M. Ruetters, C. Mertens, A. Felten et al. · 0 citations

Related blog posts

Microsoft Research Blog Nov 12, 2026

Microsoft Research Focus – Edition #98

What's new in research at Microsoft? Host Anson Ho explores the latest, including AI-powered universal translation, a breakthrough in a 31-year-old mathematics challenge, and advances making AI coding agents faster and more efficient.  The post Microsoft Research Focus – Edition #98 appeared first on Microsoft Research.

Microsoft Research Blog Nov 5, 2026

Formally verifying agent-written full-stack web apps with PDD Kit

AI agents can generate code at a scale that’s hard for humans to review line-by-line. PDD Kit helps ensure the code is doing what the developer intended by creating formal specifications and testing against them. It converts developer intent into a Verus specification, proves AI-generated code meets it for every input, and uses tests where proofs aren't practical. Developers review intent, not every line. The post Formally verifying agent-written full-stack web apps with PDD Kit appeared first o…

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.