Skip to content
Preprint

Data center cooling choices shift water impacts across the grid: An integrated water-energy model for sustainable data center development

Sep 2026 · 0 citations · 30 references
Engineering Computer Science

Abstract

Data centers are being developed at an unprecedented pace, yet their energy and water impacts, and the spatial and temporal distribution of these impacts, remain poorly characterized. Data centers consume water for cooling (direct) and through electricity generation (indirect). Decisions on siting and cooling technology result in water-energy trade-offs that extend impacts beyond the facility's location. Existing assessment frameworks rely on facility efficiency metrics and average grid water intensity factors, suppressing the temporal impacts of data center load and generation availability. They also attribute indirect consumption to the facility's location rather than to the generators (and corresponding hydrologic regions) that respond to the added load, misattributing spatial impacts. To close this gap, we develop a computational model of the data center-energy-water nexus that links facility cooling and electricity demand with hourly economic dispatch, generator-level water consumption, and monthly subbasin depletion. Built on open-source data, the model resolves where and when water is consumed, and where this consumption compounds existing water risk or creates new risk. Using the model, we study different cooling configurations and proposed developments in the state of Michigan. Air-cooled data centers halve total water consumption relative to evaporative cooling, but increase electricity demand and raise indirect water consumption by one-third, shifting the water footprint from the facility to generators. Mapping these changes to subbasins reveals depletion increases beyond the data center sites, in regions that facility-level reporting may overlook. These results show that data center water and energy impacts cannot be assessed in isolation, motivating the need for integrated modeling to inform siting, design, and reporting practices.

View source

Similar papers

Open access Nov 2026

Sustainable Data Center Planning and Operation as an Electricity–Heat–Water–Computation Coupling System: Short-Term Dispatching and Long-Term Infrastructure Planning

With the rapid development of artificial intelligence (AI) technology, data centers, as the core infrastructure supporting AI computing, are facing increasingly prominent challenges, including low resource utilization rate, high energy consumption, high power usage effectiveness (PUE), and high water consumption. To ad...

Ling-Fang Yang, Zi-Quan Zhang, Chong-Yu Wang et al. · 0 citations
Open access Oct 2026

Developing Environmental Sustainability Frameworks for Managing Energy, Water, and Emissions Impacts of Expanding Data Centres

The accelerating expansion of digital infrastructure, driven by cloud computing, artificial intelligence, high-performance computing, and increasingly data-intensive services, has intensified the environmental pressures associated with data centre development. Rising electricity demand, substantial cooling-water requir...

Bobur Bayero · 0 citations
Open access Sep 2026

One Quarter of Global Data Centers are Located in Water-Stressed Areas

The rapid growth of digital services is increasing the demand for high-performance computing within data centers, intensifying the demand for local natural resources, particularly energy and water. This study assesses the current and future exposure of all 9347 currently identified data centers worldwide to water gap c...

Lorenzo Rosa, M. Sangiorgio, B. R. Scanlon et al. · 1 citation
Conference Open access Sep 2026

Constraint-Aware Economic Decision Support for Data Center Cooling Mode Assessment

Data center cooling is a technical process with direct economic consequences, as cooling-mode decisions affect electricity consumption, water use, maintenance requirements, thermal risk, and capital expenditure. This paper develops a constraint-aware economic decision-support framework for data center cooling mode asse...

Alexey V. Zakharevsky, Vladimir A. Shiboldenkov · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.