Skip to content
Open access

Biomechanical Evaluation of PEEK Material on Three-Unit Tooth-Implant-Supported Fixed Partial Dentures: A Finite Element Analysis

Sep 2026 · Türk Doğa ve Fen Dergisi · Vol 15, pp. 125-134 · 0 citations · 23 references

TL;DR

Monolithic zirconia exhibited the lowest stress values in the bone tissue, implant, and tooth, compared with PEEK, the prosthetic material with the lowest elastic modulus, which showed the highest stress values in cortical bone and implant.

Abstract

Purpose:Polyether ether ketone (PEEK), a recently introduced material claiming to absorb stress, has been assessed in limited studies for use in tooth-implant-supported fixed partial dentures (FPDs). This study aims to evaluate the effect of prosthetic material on stress accumulation in the teeth, periodontal tissues, and implants in tooth-implant-supported FPDs using finite element analysis (FEA). Materials -Methods: Assuming that the lower right first and second molars are missing, and using computed tomography (CT), a 3D scanner, and different software, a finite element model of a three-unit dental implant-supported FPD in which the implant is placed was created. Five experimental groups (metal supported ceramic, zirconia-based ceramic, monolithic zirconia, composite coated PEEK and monolithic PEEK) were formed. The prepared models were analyzed by applying a force of 600 N to the food piece, which was modeled as a negative copy of the pontic occlusal surface, and the maximum von Mises stress values were recorded. Results: Significant differences were observed in von Mises stress values depending on the prosthetic material. Group P (the prosthetic material with the lowest elastic modulus; PEEK) showed the highest stress values in cortical bone (108.94 MPa) and implant (722.59 MPa). Stress accumulation in dentin was highest in Group PC (107.05 MPa) and lowest in Group Z (41.89 MPa). Conclusion: Monolithic zirconia exhibited the lowest stress values in the bone tissue, implant, and tooth. Stress was concentrated around the cortical bone and the implant in PEEK materials having a low elastic modulus. Prosthetic materials can significantly affect stress values.

Read PDF

Similar papers

Open access Oct 2026

Effect of Prosthodontic Material on Stress Distribution in Posterior Single Crown Supported by the Bioxide-S Symbionic Tooth: Influence of Bone Architecture in a Three-Dimensional Finite Element Analysis

Background/Objectives: The biomechanical response of posterior single crowns is influenced by restorative stiffness, device geometry, loading direction, and bone architecture. This study evaluated the effect of crown material on stress distribution in posterior single crowns supported by the Bioxide-S Symbionic Tooth (...

V. Ronsivalle, Paola Lo Giudice, Magnus Persson et al. · 0 citations
Open access Sep 2026

Finite element analysis to evaluate and compare stress distribution in fixed partial denture with pier abutment using rigid and non-rigid connector

Within the limitations of the finite element model, both the presence and location of a nonrigid connector influenced stress distribution in a 5-unit FPD supported by a pier abutment.

P. Jain, A. Gupta, Karan Jarkani et al. · 0 citations
Open access Sep 2026

Influence of Denture-Base Polymer on the Biomechanical Response of Maxillary and Mandibular Complete Dentures: A Finite Element Analysis

Objectives: To compare the biomechanical response of maxillary and mandibular complete dentures with poly(methyl methacrylate) (PMMA) and polyetheretherketone (PEEK) denture bases using patient-specific finite element analysis. Methods: Patient-specific models were reconstructed from cone-beam computed tomography data....

R. A. Omer, Jawad M. Mikaeel · 0 citations
Sep 2026

Fracture load of interim 3-unit fixed dental prostheses fabricated using contemporary CAD-CAM polymers: An in vitro study.

STATEMENT OF PROBLEM Although several studies have evaluated the mechanical properties of contemporary computer-aided design and computer-aided manufacturing (CAD-CAM) polymers for interim tooth-supported restorations, research describing mechanical testing under clinically representative conditions is limited. PURPO...

C. Jurado, Francisco X. Azpiazu-Flores, M. Antal et al. · 0 citations
Open access Oct 2026

Biomechanical assessment of titanium, zirconia, and polyetheretherketone abutments under functional loads: A finite element study.

PURPOSE To compare the biomechanical behavior of titanium, zirconia, and polyetheretherketone (PEEK) abutments in implant-supported restorations under vertical and oblique loading using finite element analysis. METHODS Three three-dimensional models were created using SolidWorks software and analyzed using finite ele...

Khaled Omran Ben Khalil, Simge Dagistan, Sinan Köse et al. · 0 citations
Open access Sep 2026

The effect of implant level in single six-support bridge-like prosthesis designs on the stress-strain state of structural elements based on three-dimensional mathematical modeling

Objective. To evaluate the stress-strain state of bone tissue supported by six dental implants under various types of occlusal loading by finite element analysis. Materials and methods. A three-dimensional finite element model of the mandibular segment with six implants and a fixed bridge prosthesis was developed. The...

S. Serebryanyy, A. Muraev, K. Salekh et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.