Skip to content
Open access

Effect of Denture Base Stiffness on Stress Redistribution in an Idealized Complete-Denture Model Under Static Bilateral Clenching: A Finite Element Analysis

Sep 2026 · Materials · Vol 19, pp. 3961 · 0 citations · 24 references
Medicine

TL;DR

Compared rigid and flexible denture base material conditions in an idealized maxillomandibular finite element (FE) model at the final static bilateral clenching step, the findings do not establish clinical adaptation, contact pressure, tissue protection, deformation, durability, or performance in immediate dentures.

Abstract

Denture base elastic-property assignment may influence how mechanical stress is distributed between a complete denture and its supporting tissues. This study compared rigid and flexible denture base material conditions in an idealized maxillomandibular finite element (FE) model at the final static bilateral clenching step. The model represented a fully edentulous geometry with coincident denture–gingiva surfaces connected by a tie constraint. The model did not include an initial interface gap, interface separation or sliding, extraction sockets, tissue remodeling, or time-dependent misfit. Geometry, mesh, boundary conditions, and loading were identical between the two conditions, whereas both the Young’s modulus and Poisson’s ratio assigned to the denture base differed. The peak magnitude of the minimum principal stress in the gingiva and the model-predicted local peak von Mises stress in the denture base elements were evaluated. Under the adopted mesh configuration, the flexible property assignment was associated with reductions of 28.6% and 35.3% in gingival compressive stress magnitude and increases of 70.5% and 73.9% in local denture base peak stress in the maxilla and mandible, respectively. These local peak differences are exploratory, model-dependent observations and have not been demonstrated to be mesh-independent. The findings do not establish clinical adaptation, contact pressure, tissue protection, deformation, durability, or performance in immediate dentures.

Read PDF

Similar papers

Open access Sep 2026

Finite element analysis to evaluate and compare stress distribution in fixed partial denture with pier abutment using rigid and non-rigid connector

Within the limitations of the finite element model, both the presence and location of a nonrigid connector influenced stress distribution in a 5-unit FPD supported by a pier abutment.

P. Jain, A. Gupta, Karan Jarkani et al. · 0 citations
Open access Sep 2026

Influence of Denture-Base Polymer on the Biomechanical Response of Maxillary and Mandibular Complete Dentures: A Finite Element Analysis

Objectives: To compare the biomechanical response of maxillary and mandibular complete dentures with poly(methyl methacrylate) (PMMA) and polyetheretherketone (PEEK) denture bases using patient-specific finite element analysis. Methods: Patient-specific models were reconstructed from cone-beam computed tomography data....

R. A. Omer, Jawad M. Mikaeel · 0 citations
Open access Nov 2026

Biomechanical Evaluation of CAD/CAM Restorative Materials for Maxillary Second Premolar Crowns Using Three-Dimensional Finite Element Analysis

Background/Objectives: This study evaluated how the elastic modulus of CAD/CAM crown materials affects the stress distribution within a maxillary second premolar and its supporting structures. Methods: A maxillary premolar was digitally reconstructed for finite element analysis. Three crown materials with differing ela...

Deedar Wahhab Kareem, R. Talabani, A. Fatalla · 0 citations
Open access Sep 2026

Finite Element Analysis of the Load-Bearing Components of a Stackable Surgical Guide System During Flapless Implant Osteotomy in a Fully Edentulous Maxilla

Highlights Finite element evaluation of a stackable surgical guide assembly for a fully eden-tulous maxilla. Under the maximum simulated drilling load, calculated stresses remained below the selected reference strengths in both contact scenarios. The polymeric guides exhibited substantially greater relative material ut...

I. Ghionea, C. Cristache, Ștefan Dumitru et al. · 0 citations
#edge computing Open access Sep 2026

Stress Distribution Pattern in Implant-Assisted Removable Partial Denture (IARPD): A 3D Finite Element Analysis

Abstract Background Removable partial dentures (RPDs) held in place by clasps have become a favored option for treating patients with partial tooth loss. However, these dentures have their drawbacks, including the issue of frequent displacement, which can lead to patient dissatisfaction and decreased usage, especially...

S. Agarwal, Subhabrata Maiti, J. Paulraj et al. · 0 citations
Open access Oct 2026

Effect of Prosthodontic Material on Stress Distribution in Posterior Single Crown Supported by the Bioxide-S Symbionic Tooth: Influence of Bone Architecture in a Three-Dimensional Finite Element Analysis

Background/Objectives: The biomechanical response of posterior single crowns is influenced by restorative stiffness, device geometry, loading direction, and bone architecture. This study evaluated the effect of crown material on stress distribution in posterior single crowns supported by the Bioxide-S Symbionic Tooth (...

V. Ronsivalle, Paola Lo Giudice, Magnus Persson et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.