Three-Phase Photovoltaic System with Battery Energy Storage and Volt–VAR Reactive Power Support: Architecture Assessment and Integrated Control Proposal
Abstract
The growing share of photovoltaic generation in power grids intensifies the need for converter architectures capable of combining efficient energy conversion, DC-bus stability, and ancillary service provision at the grid coupling point. This paper presents the modeling, implementation, and simulation-based evaluation of a 91 kWp three-phase photovoltaic (PV) system integrated with a battery energy storage system (BESS), developed in the PLECS environment. The proposed architecture comprises three interleaved Boost stages for maximum power point tracking (MPPT), a DC bus regulated at 600 V, three independent bidirectional buck–boost converters for LiFePO4 bank management, and a two-level three-phase voltage source inverter (VSI) with an LC output filter. The control is organized in cascade voltage–current loops for the DC–DC stages and in vector control within the synchronous reference frame (SRF) for the inverter, with synchronization via SRF-PLL. A C-Script supervisory block integrates the Perturb and Observe (P&O) MPPT algorithm, independent state of charge (SOC) estimation per bank via coulomb counting, and Volt–VAR reactive power reference generation with a dead band of 0.90–1.10 pu. Five scenarios are analyzed for validation: DC-bus regulation under irradiance transients; reactive power support during undervoltage and overvoltage events (0.80–0.85 pu and 1.15–1.20 pu); BESS operation as an active DC-link support element; and PV curtailment with fully charged banks. All five scenarios were additionally corroborated on a Typhoon HIL402 Pro 2 hardware-in-the-loop platform, reproducing the PLECS waveforms within the amplitude and timing resolution of the oscilloscope captures. Across all scenarios, the DC bus is held within ±15 V (2.5%) of the 600 V reference, with the worst-case transient recovering in 80–100 ms; under a sustained 9 s bidirectional disturbance, redirecting PV surplus to BESS charging in both the undervoltage and overvoltage segments—with no externally imposed active-current limit—keeps the current-vector magnitude id2+iq2 below the 335 A rating throughout (≈271 A and ≈242 A, respectively), while the available reactive margin Qdisp reaches ≈78– 80 kVAr in both segments and the bank SOC advances by ≈0.03 pu; and supervisory curtailment under a sustained overvoltage ride-through with a saturated bank keeps the per-bank SOC dispersion within 4×10−5 pu while expanding the available reactive margin Qdisp from ≈50 to ≈90 kVAr.