Sep 2026· International Journal of Marine Engineering Innovation and Research· Vol 11, pp. 1064-1073· 0 citations
Abstract
This study proposes a standards-based design for integrating a 50/60 Hz shore power frequency converter to supply international vessels that operate at 60 Hz from a 50 Hz shore grid, while preserving electrical safety through adequate protection and conductor ampacity in a low-voltage shore connection (LVSC) system. A case study was conducted at The anonymized Surabaya terminal, which provides a 400 V, 50 Hz shore power service through five berth panels. The analysis adopts a conservative full-load basis of 250 A per berth panel and estimates converter capacity using three-phase power relations. The integration architecture is selected to reduce operational coupling between berths, while protection and cable adequacy are verified using a 125% margin rule (PUIL-based) and the LVSC interoperability framework of IEC/IEEE 80005-3 to justify frequency conversion for international-vessel service.
Results show a required active power of 147.05 kW per berth panel, corresponding to 735.25 kW total for five panels. A distributed one-converter-per-panel scheme using 200 kW modules yields approximately 73.5% nominal utilization per unit and supports practical deployment as three units for the domestic terminal and two units for the international terminal. In addition, the standards-based verification identifies targeted infrastructure upgrades required for robust operation under peak loading: MCCB GU III is under-rated for the aggregated domestic load (750 A) and should be uprated to 1250 A, while the ACB–Transformer feeder is the dominant thermal bottleneck and requires an ampacity upgrade to satisfy the minimum margin. Overall, the findings indicate that reliable 50/60 Hz interoperability depends on coordinated converter sizing and distributed integration, together with focused uprating of upstream protection and conductor capacity.
Voltage instability in domestic electricity supplies can adversely affect the performance and reliability of household appliances and sensitive electronic equipment. This study presents the design and experimental evaluation of a 1 kVA voltage stabilizer based on a capacitor bridge cascade model (CBCM) for improved hou...
Reginald Beda Matola, Emanuel Steven Matee, Aviti Thadei Mushi· Journal of ICT Systems· 0 citations
To meet the low-voltage, high-current, and long-duration requirements of thermal and dynamic stability tests for UHV disconnectors and earthing switches, this paper proposes a two-stage step-down test system powered by a 330 kV grid. The system employs a 12.5 MVA transformer (330 kV/35 kV) and a 90 MVA short-time-rated...
Zhi-Lin Kang, Yu-Lin Kang, Jian-Zhen An et al.· Journal of Physics, Conferen...· 0 citations
The maritime transport sector is a major source of pollutant emissions, posing severe health risks especially in port cities. While shore-to-ship (S2S) power connections are an effective solution to decarbonize ports, their implementation presents significant technical challenges. Specifically, S2S connections must com...
Borja Abal-Calvar, Diego Ríos-Castro, Diego Pérez-Estévez et al.· Applied Sciences· 0 citations
Deep voltage sags represent a critical challenge in power-from-shore supply to offshore platforms, as they can cause variable-speed drives to trip and interrupt essential processes. This paper investigates energy-storage-integrated flexible AC transmission solutions (FACTS) for voltage sag mitigation, with a focus on c...
J. K. Banda, Arkaitz Rabanal, Salvatore D'Arco· 2026 Energy Conversion Congr...· 0 citations
This paper presents a measurement-validated power quality assessment of a grid-connected wind farm in Jordan based on synchronized field measurements and validated simulation studies. The increasing penetration of large-scale wind farms into modern power systems introduces significant power quality challenges, particul...
Malik K. Alkasasbeh, B. Ismail, C. Charin et al.· Electrica· 0 citations
Inductive and nonlinear loads in office buildings increase reactive power demand, lower the power factor, and inject harmonic currents into low-voltage distribution panels. The power quality of the Rectorate Building of Universitas Khairun, Ternate, has not been assessed despite its growing demand. This study evaluates...
R. Mustafa· PROtek : Jurnal Ilmiah Tekni...· 0 citations