Oct 2026· Japanese Dental Science Review· Vol 62, pp. 284 - 307· 1 citation· 78 references
Medicine
TL;DR
Findings highlight the potential role of robotic CAIS for managing complex cases and full-arch rehabilitations, providing enhanced predictability and safety and high-quality randomized control trials are required to further validate long-term outcomes.
Abstract
Robotic systems are increasingly integrated into dental implantology, yet their accuracy and clinical reliability remain under evaluation. This systematic review and meta-analysis synthesized evidence on the accuracy of robot-assisted dental implant placement and explored the influence of clinical variations on outcomes. Comprehensive searches of PubMed, Scopus, and Embase (January 2015–September 2025) identified 39 clinical studies involving 1227 patients and 2066 implants. Risk of bias was assessed using validated tools for randomized, non-randomized, and observational studies. Pooled estimates revealed mean deviations of 0.68 mm coronally (95% confidence interval [CI]: 0.62–0.74), 0.72 mm apically (95% CI: 0.66–0.79), and 1.60° angularly (95% CI: 1.40–1.81). Subgroup analyses demonstrated that autonomy level significantly influenced accuracy, with task-autonomous and semi-autonomous systems outperforming haptic-guided approaches. Conversely, edentulous span, implant location, and study design did not significantly affect outcomes. Robotic systems consistently achieved superior accuracy over previously reported computer-assisted implant surgery (CAIS) methods, with deviations well within clinically accepted limits. Higher autonomy levels were associated with increased accuracy across diverse clinical scenarios. These findings highlight the potential role of robotic CAIS for managing complex cases and full-arch rehabilitations, providing enhanced predictability and safety. High-quality randomized control trials are required to further validate long-term outcomes.
ABSTRACT Background Robotic‐assisted unicompartmental knee arthroplasty (rUKA) aims to enhance the precision and reproducibility of implant positioning compared with manual UKA (mUKA). This systematic review and meta‐analysis compared radiographic, clinical, and patient‐reported outcomes between rUKA and mUKA. Methods...
S. Kanakala, K. Sugand, Jennifer Tasong et al.· Orthopaedic Surgery· 0 citations
This systematic review evaluated the positional accuracy, safety, and clinical performance of digitally guided orthodontic mini-implant placement. English full-text studies published from 2015 to July 2026 evaluating digitally guided TAD placement and reporting accuracy, safety, or procedural outcomes were eligible; re...
Duarte Sá, Maria João Calheiros-Lobo, T. Pinho· Hygiene· 0 citations
A comprehensive systematic review of the major robotics utilized in cranial neurosurgical procedures and their respective outcomes for articles published between January 2000 to February 2025.
Alison E. Burgess, Bailey D. Lupo, Luke P. Landry et al.· Neurosurgical review· 0 citations
OBJECTIVES
To systematically evaluate the accuracy of dental implant placement guided by augmented reality (AR) or mixed reality (MR) and to identify key clinical and technical factors influencing deviations.
DATA
This systematic review adhered to PRISMA guidelines and was registered in PROSPERO (CRD420251178583). St...
Bo-Xuan Xu, Wei-Shao Lin, Jian-Guo Tan et al.· E -journal of dentistry· 0 citations
PURPOSE
Robot-assisted total hip arthroplasty (R-THA) is being adopted progressively because of its potential to improve implant positioning and restore hip biomechanics more accurately than conventional techniques. However, whether these technical advantages translate into meaningful clinical benefits remains uncertai...
E. Muñoz-Mahamud, Miquel Cortés-Rovira, A. Alías-Petralanda et al.· International Orthopaedics· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.